8
OM-LHP
Main Burner Orifice
1.
Remove the control knobs and front panel.
2.
Unscrew the bolts and pilot valve, and remove the manifold.
3.
Replace the correct orifice fittings for the gas type into the valve.
4.
Replace the front control panel and tighten the four (4) screws on the front to
secure the panel in place.
5.
Replace the control knobs on the front control panel. The control knobs are a
push fit onto the shafts of the gas control valves.
6.
Before installing the regulator, unscrew the hexagonal cap.
If you can read (NAT) on the plastic insert extending out of the cap, flip it over
and snap it back in (see illustration at left).
7.
Continue with installation.
Manifold
NOTE: Unit number on
side of orifice fittings
Regulator with Brass Cap
LP Position
of Insert
Gas Type Conversion
HOT PLATE
IGNITION
Summary of Contents for LHP212MPF