Cleaning & Maintenance
To avoid product damage, use only non-abrasive clean-
ers. Abrasive cleaners could scratch the finish of your unit,
marring its appearance and making it susceptible to dirt
accumulation. Do not use steel wool, other abrasive cleaners
or cleaners/sanitizers containing chlorine, iodine, ammonia
or bromine, as these will deteriorate the stainless steel and
glass materials and shorten the life of the unit.
Daily Cleaning
1.
Thoroughly clean back, sides, top and front of unit.
2.
Clean grates.
Weekly Cleaning
1.
Clean unit thoroughly. Clean stainless steel or chromed surfaces with a damp
cloth and polish with a soft dry cloth. A detergent may be used for cleaning.
Use a non-abrasive cleaner to remove discolorations.
2.
Remove the drip pan by pulling it out of the opening in the front panel. To
replace the pan, reverse this procedure.
3.
Burner air shutter openings and main burner ports must be kept clean. To clean
burners, boil them in a strong solution of lye water for 15 to 20 minutes. Then
clean gas ports with a sharp-pointed metal instrument to insure open ports.
Regulator Cleaning
Clean the regulator at least once a month. Make sure the vent opening is open and
not blocked in any way. Failure to do so will cause variations in pressure. This can
affect how the unit functions and may shorten the life of the product.
Once a month, clean the area surrounding vent opening (see illustration on left) with a
clean, wet rag to remove accumulated dust, dirt, lint etc.
Regulator
Vent opening