LOKERMANN GRAND PIPE 270 MULTI User Manual Download Page 3

1

Installation

warning

INSTALLATION WARNING

This machine is certified according to 60974-10:2014 Arc Welding Equipment Part 10: Electromagnetic 

compatibility (EMC) requirement and the EUT belongs to Group 2 Class A.

WARNING: This Class A equipment is intended for industrial use and it is not intended for use in 

residential locations where the elctrical power is provided by the public low-voltage supply system. 

There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to 

conducted as well as radiated disturbances.

WARNING: This equipment does not comply with IEC 61000-3-12. If it is connected to a public low-

voltage system, it is the responsability of the installer or user of the equipment to ensure, by consultation 

with the distribution network operator if necessary, that the equipment may be connected.

Assessment of area

Before installing arc welding equipment the user shall make an assessment of potential

electromagnetic problems in the surrounding area. The following shall be taken into account:

a) other supply cables, control cables, signalling and telephone cables, above, below and

adjacent to the arc welding equipment;

b) radio and television transmitters and receivers;

c) computer and other control equipment;

d) safety critical equipment, for example guarding of industrial equipment;

e) the health of the people around, for example the use of pacemakers and hearing aids;

f) equipment used for calibration or measurement;

g) the immunity of other equipment in the environment. The user shall ensure that other

equipment being used in the environment is compatible. This may require additional

protection measures;

h) the time of day that welding or other activities are to be carried out.

The size of the surrounding area to be considered will depend on the structure of the building

and other activities that are taking place. The surrounding area may extend beyond the

boundaries of the premises.

Methods of reducing emissions-Public supply system

Arc welding equipment should be connected to the public supply system according to this manual 

recommendations. If interference occurs, it may be necessary to takeadditional precautions such as 

filtering of the public supply system. Consideration should be given to shielding the supply cable of 

permanently installed arc welding equipment, in metallic conduit or equivalent. Shielding should be 

electrically continuous throughout its length. The shielding should be connected to the welding power 

source so that good electrical contact is maintained between the conduit and the welding power 

source enclosure.

Maintenance of the arc welding equipment

The arc welding equipment should be routinely maintained according to this manual

recommendations. All access and service doors and covers should be closed and properly

fastened when the arc welding equipment is in operation. The arc welding equipment should

not be modified in any way, except for those changes and adjustments covered in this manaul. In 

particular, the spark gaps of arc striking and stabilising devices

should be adjusted and maintained according to our recommendations.

Welding cables

The welding cables should be kept as short as possible and should be positioned close

together, running at or close to the floor level.

Equipotential bonding

Bonding of all metallic objects in the surrounding area should be considered. However,

metallic objects bonded to the work piece will increase the risk that the operator could receive

an electric shock by touching these metallic objects and the electrode at the same time. The

operator should be insulated from all such bonded metallic objects.

Earthing of the workpiece

Where the workpiece is not bonded to earth for electrical safety, nor connected to earth

because of its size and position, for example, ship’s hull or building steelwork, a connection

bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be 

taken to prevent the earthing of the workpiece increasing the risk of injury to users or damage to other 

electrical equipment. Where necessary, the connection of the workpiece to earth should be made by 

a direct connection to the workpiece, but in some countries where direct connection is not permitted, 

the bonding should be achieved by suitable capacitance, selected according to national regulations.

Screening and shielding

Selective screening and shielding of other cables and equipment in the surrounding area may

alleviate problems of interference. Screening of the entire welding area may be considered for

special applications.

Summary of Contents for GRAND PIPE 270 MULTI

Page 1: ...RAND PIPE 270 M U L T I IMPORTANT Read this OPERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your deal...

Page 2: ...nt 3 4 Power supply input connection 3 5 Polarity Connection MMA 3 6 Assembling the equipment TIG 4 OPERATION 4 1 Layout for the panel 4 2 Control Panel 4 3 Argon Arc Welding Operation 4 3 1 TIG weldi...

Page 3: ...ring of the public supply system Consideration should be given to shielding the supply cable of permanently installed arc welding equipment in metallic conduit or equivalent Shielding should be electr...

Page 4: ...acters such as stable welding arc low tungsten pole loss more welding current narrow and deep weld 3 DC Pulsed TIG has the following characters 1 Pulse heating Metal in Molten pool has short time on h...

Page 5: ...60 TIG MMA TIG MMA TIG MMA Rated input Power I1max KW 7 5 9 5 7 5 10 2 6 7 9 5 Rated input Current A 19 24 11 15 9 13 Duty Cycle 40 10min 40 270A 60 225A 100 175A 30 250A 60 180A 100 140A 40 270A 60...

Page 6: ...g machines power supply connects to 110V 460V When the power supply voltage is over the safe work voltage there are over voltage and under voltage protection inside the welder the alarm light will on...

Page 7: ...accessory codes When GRAND PIPE 270 MULTI welding machines are operated in HF ignition method the ignition spark can cause interferences in equipment near the welding machine Be sure to take specially...

Page 8: ...dial shown on the display during welding The illustration below shows an overview of the main settings needed for day to day working using the GRAND PIPE 270 MULTI control panel as an example You will...

Page 9: ...been pressed 7 Pulse frequency Unit Hz Setting range 0 5 200 Factory setting Important Only selectable when pulse key has been pressed 8 Downslope time Unit S Setting range 0 0 10 0 Factory setting 9...

Page 10: ...n is turned off the output current is the welding current Iw t4 Repress down the gun switch the output current slopes down to crater current if the output pulse function is turned on the slope down cu...

Page 11: ...the using life of the tungsten electrode and prevent tungsten clipping 3MMA operation if the electrode touches workpiece over two seconds the welding current will drop to the 0 automatically to prote...

Page 12: ...r watch listen if thearc welding machine has shaking whistle calling or peculiar smell If there is one of the above problems find out the reason and clear it If you can t find out the reason please co...

Page 13: ...e damaged Repair or change it The earth cable connected unstably Check the earth cable The welding cable is too long Use an appropriate welding cable There is oil or dust on the workpiece Check and re...

Page 14: ...5 3 Electrical principle drawing...

Page 15: ......

Page 16: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 lokermann lokermann eu www lokermann eu...

Reviews: