background image

SPECIFICATIONS

Specification of ADF

1.CE Classification

1/1/1/1

2.Real Vision

Yes

3. LCD Viewing area

100 x 60 mm  (3.94" x 3.28")

4. Light State Shade  

DIN 4

5. Dark Variable Shades

DIN 5-9 / 9-13

6. Switching time (light to dark)

0.08ms

7. Delay time (dark to light)

Adjustable (Level 1-5 for 0.1-0.9s)

8. Sensitivity  

Adjustable (Level 1-5 for low-high)

9. Arc Sensors

4

10.grinding Function

Yes  

11. Cutting Function

Yes,Shade 5~8 adjustable

12. Power Supply

Solar and Li-ion rechargeable battery 

13.ADF Battery Operating time 

>300h

14.Charging time 

3.5h

15.Charging Frequency

>500

16. Operating Temperature

-10°C~65°C (14°F~149°F)

17. Inside PC lens

103 x 63 x 1 mm

18. Outside PC lens

118 x 97 x 1 mm 

19. Inner visor

Clean Visor

20. Standards

CE EN379, ANSI Z87.1, CSA Z94.3, AS/NZS

Specification of  Remote

1.Display

OLED

2.Power Supply

Li-ion rechargeable battery

3.ADF Battery Operating time 

>300h

4.Charging time 

3.5h

5.Charging Frequency

>500

                 Specification of  Respirator System

Size

(Blower Assembly)

9-2/5 x 6-1/2 x 2-3/4 in. (240 x 165 x 70 mm)

Weight

2.4KG

Particle Filter

1*TH3 P R SL

Air Flow

Manufacturer minimum design flow rate: 165L/min

Nominal airflow :

Level 1: 170L/min

Level 2: 200L/min

Level 3: 230L/min

Noise Level

Max 75dB

Operate Temperature

23  to 131  (-5 ~55 )

Storage temperature

14℉ to 131℉ (-10℃~55℃)

Summary of Contents for GRAND AIR HD

Page 1: ...GRAND AIR HD USER MANUAL...

Page 2: ...eye splash protection must be used when these hazards are presented Impact resistant primary eye protection spectacles or goggles that meet current ANSI specifications must be worn at all times when...

Page 3: ...Charging Frequency 500 16 Operating Temperature 10 C 65 C 14 F 149 F 17 Inside PC lens 103 x 63 x 1 mm 18 Outside PC lens 118 x 97 x 1 mm 19 Inner visor Clean Visor 20 Standards CE EN379 ANSI Z87 1 C...

Page 4: ...g parts for signs of wear or damage Any scratched cracked or pitted parts should be replaced immediately This ADF is fully controlled by a Remote control and connected with Bluetooth All the adjustmen...

Page 5: ...ication 1 low to 5 high Delay indication 1 short 0 1s to 5 long 0 9s Shade reading Cutting mode indication Grind mode indication MODE SETTING ADF has 4 function modes Welding mode Shade range 5 9 Weld...

Page 6: ...ivity will be increased Or Anticlockwise rotate the button on the Remote Control Sensitivity will be reduced After the Icon 6 mentioned is displayed on the screen number will be changed during 1 to 5...

Page 7: ...er will be increased Or Anticlockwise rotate the button on the Remote Control Shade number will be reduced The Shade range at cutting mode is 5 8 Note Do not weld in the cutting mode BATTERY INDICATOR...

Page 8: ...ng angles are different Operator may adjust the headband in 5 parameters 1 Select eye level by Headband adjusting buttons 1 2 Select view angle by Segmental positioning plate 2 3 Adjust head size peri...

Page 9: ...ructure inside the flip up cover position 1 Take the ADF out Position 2 replace a new outer protect lens Insert the ADF back to flip up cover lock the ADF by push the lock structure The user must alwa...

Page 10: ...protection system turbo unit filter waist belt 3 Lithium ion battery 4 The tube its anti fire cloth and both end fittings 5 The shoulder harness 6 The air flow tester 7 The lithium ion battery charge...

Page 11: ...ed at a 100 before the first use It is recommended to charge the batteries at a 100 before each use The charger must not be used for anything else than it was designed for Do not charge the battery in...

Page 12: ...keep the charger plugged to the mains if it s not in use INSTALLING THE RESPIRATORY SYSTEM ON THE BELT 1 Remove the belt s release buckle 2 Remove the fastening belt from the waist connector s 2 belt...

Page 13: ...ed protection If any component is missing or if anything is not clear contact the supplier BEFORE USE FITTING AIR FLOW TEST 1 Connect the breathing tube to the turbo unit and twist it clockwise to loc...

Page 14: ...djust the headgear to suitable tightness push and turn left to loosen turn right to tighten Make sure the face seal is positioned properly otherwise you can t get sufficient sealing needed to offer th...

Page 15: ...f the turbo unit has turned off for more than 30 minutes Pressing the ON button can activate the system 3 The Respiratory system must be operated in the temperature range of 5 to 55 and relative humid...

Page 16: ...o dealer if LCD still shows E01 Fault code E02 blinks 1 Motor is damaged 2 Motor impeller rubs blower shell 3 Circuit has excessive current Check and remove physical failure and restart the system Ret...

Page 17: ...7 36006 Inner Protection Lens 104 5x64x1mm 5pcs 8 36007 Auto Darkening Filter ADF 36010 ADF Remote Control 9 36008 Outer Protection Lens 118x97x1mm 5pcs 10 39002 Filter Cover 11 39003 Spark Arrestor 1...

Page 18: ......

Page 19: ...for a period of 100ms Gray is the beep sound and blank grid is a quiet period If several continued grids are in gray then there s a continuous beep sound For example when the current is overloaded th...

Page 20: ...o The Grand Air unit has been used solely for the purpose for which it is intended The Grand Air unit has not been subject to misuse accident modification or repair In the event of a claim contact the...

Page 21: ...at the GRAND AIR HD compies with the following regulations in force EN 12941 1998 EN 12941 1998 A1 2003 EN 12941 1998 A2 2008 EN 175 EN 379 LOKERMANN S r l Via Produzione 16 18 37044 Cologna Veneta VR...

Page 22: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 sales lokermann eu www lokermann eu...