Chimney

Effective height of the chimney should be at least 4 meters (measured from the hearth of the stove). For detailed
calculations, please refer to standard EN 13384-1.

4. TRANSPORT

Transport should be handled by experts with appropriate equipment. 

Packaging

Stove is tightly fixed onto a palette.

Please check the stove for possible damages and that is contains all ordered parts.

If you do find any damages, please report them to your stove supplier immediately.

Handling of the stove

Stoves should be moved with a palette, standing upside-down. Move it carefully so it does not tip over!

Avoid shocks and vibrations.

Once in place, dismount it and proceed with the installation.

Cover of the stove is breakable. It must not be loaded. 

5. INSTALATION INSTRUCTIONS

General (Air inlet is optional)

Please do not overload the stove.

All the packing material should be removed from hearth and ash pan.

Check out functionality of movable parts (front door etc.) 

Build outer air flaps into facade 

Mount smoke flap onto chimney funnel

Connect chimney funnel. Chimney thickness and insulation must be in accordance with country's and EU
construction regulations.

Chimney must not apply additional pressure on the stove. 

Minimum diameter of the chimney should be taken into consideration.

Measured values, gathered in this document, corresponds to the calculations of chimney with the following
dimensions - 4 m height; diameter 150 mm.

Air supply connection

For stove to work properly, continuous air supply is required.

If upper requirement is not met, additional air supply can be provided through air connection (Ø100mm)
which is located at the back of the stove.

Airflow is being regulated with air taps, which are built-in, into air supply conduit.

Please   note   that   during   winter   times,   cold   air   surges   can   generate   condense   on   stove   parts   and   thus
compromise its functionality.

Repair advice

Glass frame and most of the movable parts can be removed once the stove is installed.

Repairs can only be performed by a professional in agreement with the supplier/manufacturer 

Repair instructions are not part of this document

if necessary, refer to your local dealer of service agent.

Lokaterm                                                              November-2015                                                             page 9

Summary of Contents for CABANO

Page 1: ...CREINA d d Mirka Vadnova 8 4000 KRANJ Tel 04 20 13 350 Fax 04 20 13 363 E mail INFO CREINA SI www lokaterm com www creina si Users manual Installation Operating and Maintenance Instructions CABANO...

Page 2: ...1 MANUFACTURER PRODUCT TYPE 3 2 USER MANUAL 5 2 1 STOVE DESCRIPTION 6 2 2 INITIAL IGNITION 7 2 3 LOADING FIREWOOD 7 2 4 CLEANING OF THE STOVE 8 2 5 BREAKDOWNS AND CAUSES 8 3 MOUNTING INSTRUCTIONS 9 4...

Page 3: ...mensions of the stove Cabano Lokaterm November 2015 page 3 Product Type Cabano Standard EN 13240 Smoke outlet diameter 148 mm Nominal thermal power 6 kW Efficiency 73 CO emissions 13 O2 1250 mg m3 Dus...

Page 4: ...urning natural firewood ex beech birch wood briquettes and briquettes made of brown coal Emission limitation It is forbidden to burn the following materials in stoves Impregnated or moist wood wood ch...

Page 5: ...on only during the heating up of the stove approximately the first 10 minutes of burning Normal operation area only the air inlet above the door is open secondary air This is an area within which the...

Page 6: ...inal heat output 6 kW is generated when the regulator is set to Medium power position and there is aprox 2 5 kg of firewood inside of stove and the draught is at 12 Pa Some of the air which is heated...

Page 7: ...et flap opened Is the air regulator handle opened Is the fresh air supply sufficient Is the firewood dry the stove doesn t heat up Is the air regulation handle in opened position the stove is overheat...

Page 8: ...ammable and explosive substances or their mixtures are being manufactured processed or stored In rooms that are ventilated and not have safety devices that prevent negative pressure In rooms that have...

Page 9: ...outer air flaps into facade Mount smoke flap onto chimney funnel Connect chimney funnel Chimney thickness and insulation must be in accordance with country s and EU construction regulations Chimney mu...

Page 10: ...The manufacturer obliges himself to repair any defects within 45 days from the reporting day at the latest The warranty does not cover Damages during transport and assembly Damages and defects on the...

Reviews: