![Lokaterm CABANO User Manual Download Page 9](http://html1.mh-extra.com/html/lokaterm/cabano/cabano_user-manual_1938164009.webp)
User Manual
Installation, Operating and Maintenance Instructions Stove Cabano
Chimney
Effective height of the chimney should be at least 4 meters (measured from the hearth of the stove). For detailed
calculations, please refer to standard EN 13384-1.
4. TRANSPORT
Transport should be handled by experts with appropriate equipment.
Packaging
Stove is tightly fixed onto a palette.
Please check the stove for possible damages and that is contains all ordered parts.
If you do find any damages, please report them to your stove supplier immediately.
Handling of the stove
Stoves should be moved with a palette, standing upside-down. Move it carefully so it does not tip over!
Avoid shocks and vibrations.
Once in place, dismount it and proceed with the installation.
Cover of the stove is breakable. It must not be loaded.
5. INSTALATION INSTRUCTIONS
General (Air inlet is optional)
Please do not overload the stove.
All the packing material should be removed from hearth and ash pan.
Check out functionality of movable parts (front door etc.)
Build outer air flaps into facade
Mount smoke flap onto chimney funnel
Connect chimney funnel. Chimney thickness and insulation must be in accordance with country's and EU
construction regulations.
Chimney must not apply additional pressure on the stove.
Minimum diameter of the chimney should be taken into consideration.
Measured values, gathered in this document, corresponds to the calculations of chimney with the following
dimensions - 4 m height; diameter 150 mm.
Air supply connection
For stove to work properly, continuous air supply is required.
If upper requirement is not met, additional air supply can be provided through air connection (Ø100mm)
which is located at the back of the stove.
Airflow is being regulated with air taps, which are built-in, into air supply conduit.
Please note that during winter times, cold air surges can generate condense on stove parts and thus
compromise its functionality.
Repair advice
Glass frame and most of the movable parts can be removed once the stove is installed.
Repairs can only be performed by a professional in agreement with the supplier/manufacturer
Repair instructions are not part of this document
if necessary, refer to your local dealer of service agent.
Lokaterm November-2015 page 9