User Manual
Installation, Operating and Maintenance Instructions                                                                Stove Cabano

  1. MANUFACTURER / PRODUCT TYPE

LOKATERM

Tel.: +386 (0)4 20 13 350

Creina d.d.

Fax: +386 (0)4 20 13 363

Ulica Mirka Vadnova 8

E-mail:      

[email protected]

4000  Kranj  / SLOVENIJA

Website:   

www.lokater

 

 m.com

Technical data

Figure 1: Dimensions of the stove Cabano

Lokaterm                                                              November-2015                                                             page 3

Product Type

Cabano

Standard:

EN 13240

Smoke outlet diameter:

Ø 148 mm

Nominal thermal power:

6 kW

Efficiency:

73 %

CO – emissions (13% O

2

)

1250 mg/m

3

Dust emissions

40 mg/m

3

Exhaust smoke temperature:

299 °C

Exhaust smoke volume:

7,7 g/s

Flue draught at nominal power

12 Pa

Outdoor air intake:

Ø 100 mm

Dry weight:

130 kg / 220 kg

Dimensions of the stove Dia x Height

806 mm x 1041 mm x 508 mm

Safety disatance

Sides and back 400 mm / front 1250 mm

 

Summary of Contents for CABANO

Page 1: ...CREINA d d Mirka Vadnova 8 4000 KRANJ Tel 04 20 13 350 Fax 04 20 13 363 E mail INFO CREINA SI www lokaterm com www creina si Users manual Installation Operating and Maintenance Instructions CABANO...

Page 2: ...1 MANUFACTURER PRODUCT TYPE 3 2 USER MANUAL 5 2 1 STOVE DESCRIPTION 6 2 2 INITIAL IGNITION 7 2 3 LOADING FIREWOOD 7 2 4 CLEANING OF THE STOVE 8 2 5 BREAKDOWNS AND CAUSES 8 3 MOUNTING INSTRUCTIONS 9 4...

Page 3: ...mensions of the stove Cabano Lokaterm November 2015 page 3 Product Type Cabano Standard EN 13240 Smoke outlet diameter 148 mm Nominal thermal power 6 kW Efficiency 73 CO emissions 13 O2 1250 mg m3 Dus...

Page 4: ...urning natural firewood ex beech birch wood briquettes and briquettes made of brown coal Emission limitation It is forbidden to burn the following materials in stoves Impregnated or moist wood wood ch...

Page 5: ...on only during the heating up of the stove approximately the first 10 minutes of burning Normal operation area only the air inlet above the door is open secondary air This is an area within which the...

Page 6: ...inal heat output 6 kW is generated when the regulator is set to Medium power position and there is aprox 2 5 kg of firewood inside of stove and the draught is at 12 Pa Some of the air which is heated...

Page 7: ...et flap opened Is the air regulator handle opened Is the fresh air supply sufficient Is the firewood dry the stove doesn t heat up Is the air regulation handle in opened position the stove is overheat...

Page 8: ...ammable and explosive substances or their mixtures are being manufactured processed or stored In rooms that are ventilated and not have safety devices that prevent negative pressure In rooms that have...

Page 9: ...outer air flaps into facade Mount smoke flap onto chimney funnel Connect chimney funnel Chimney thickness and insulation must be in accordance with country s and EU construction regulations Chimney mu...

Page 10: ...The manufacturer obliges himself to repair any defects within 45 days from the reporting day at the latest The warranty does not cover Damages during transport and assembly Damages and defects on the...

Reviews: