Logosol Multifunctional Servo Drive LS-231g3SB
Doc # 712231005 / Rev. C, 09/13/2018
INPUTS
Bit
Name
Description
INbit0
StatusBit5
SW4=OFF – Diagnostic / Limit1 / HomeIN
SW4=ON – Diagnostic / HomeIN
See HomeSEL1 and HomeSEL2 for details
INbit1
StatusBit6
SW4=OFF – Diagnostic / Limit2 / Input10 / Input11
SW4=ON – Diagnostic / SingleLIMIT / Input10 / Input11
INbit2
StatusBit3
Power_on diagnostic bit.
INbit3
HomeIN
Home Input. (CN9pin6/CN5pin14). Pin=HIGH, Bit=‘1’
INbit4
Limit1
SW4=OFF – Reverse Limit. (CN9pin4/CN5pin7) Pin=HIGH, Bit=‘1’
SW4=ON – Same as HomeIN (CN9pin6/CN5pin14). Pin=HIGH, Bit=‘1’
INbit5
Limit2 / SingleLIMIT
SW4=OFF – Forward Limit. (CN9pin2/CN5pin15) Pin=HIGH, Bit=‘1’
SW4=ON – SingleLIMIT (CN9pin4/CN5pin7) Pin=HIGH, Bit=‘1’
INbit6
BridgeSTA
1= Limit Switches BRIDGED.
INbit7
AEN
Amplifier enable input. (CN8pin12) Pin=HIGH, Bit=‘1’ (Mode dependant function)
INbit8
Enable
(Enable/Stop)
Hardware Enable/Stop input. (CN3pin4 & CN4pin4)
Pin=HIGH, Bit=‘1’ = Drive enable.
Pin=LOW, Bit=‘0’ = Hardware stop.
INbit9
Input9
None dedicated input. (CN3pin6/CN4pin6) Pin=HIGH, Bit=‘1’
INbit10
Input10
None dedicated input. (CN2 pin2) Pin=HIGH, Bit=‘1’
INbit11
Input11
LDCN mode - None dedicated input. (CN9pin7) Pin=HIGH, Bit=‘1’
Amplifier modes - Hardware Bridge input. (CN9pin7) Pin=HIGH, Bit=‘1’ Limit Switches bridged.
INbit12
DE
Drive enable status bit. LDCN mode = PIC_AE, Other modes = Amplifier Enable state.
INbit13
Reserved.
N.A.
INbit14
Dir
Multifunctional input. (CN8pin7) Pin=HIGH, Bit=‘1’ (Mode dependant function)
INbit15
FAULT
0 = FAULT relay contact closed.
1 = FAULT relay contact open.
OUTPUTS
Bit
Name
Description
OUTbit0
BrakeMODE
0 = Brake/Output1 depends on Servo drive state. See diagnostic tables.
1 = Brake/Output1 is following Output1 bit:
Bit=’0’, Brake/Outpu1(CN1pin4) = OFF
Bit=’1’, Brake/Outpu1(CN1pin4) = HIGH
OUTbit1
Output1
OUTbit2
Output2
(CN2pin3)
Bit=’0’, Output2=OFF
Bit=’1’, Output2=HIGH
OUTbit3
N.A.
Reserved – clear to ‘0’
OUTbit4
HomeSEL1
Select homming input source, Motor and Master encoders latch source.
HomeSEL2
OUTbit8
HomeSEL1
OUTbit4
StatusBit5
INbit0
StatusBit6
INbit1
Motor encoder latch
source
Master encoder latch
source
0
0
Limit1
Limit2/SingleLIMIT
Motor Encoder phase Z
Master Encoder phase Z
0
1
HomeIN
Input10
1
0
HomeIN
Input10
Input10 (change)
1
1
HomeIN
Input11
Input11 (change)
OUTbit5
Bridge
Limit relay contact
UserREL
OUTbit6
Bridge
OUTbit5
Input11
LDCN mode
Limit Relay
Amplifier mode
Limit Relay
0
0
0
Depends on Limit1 and Limit2.
0
1
0
Closed. BridgeSTA = 1
Depends on Limit1 and Limit2.
0
0
1
Depends on Limit1 and Limit2.
Closed. BridgeSTA = 1
1
0
X
General purpose user relay - Open
General purpose user relay - Closed
1
1
X
OUTbit6
UserREL
OUTbit7
SmartSTOP
SmartSTOP
1= Enables the SmartSTOP timer and hardware logic.
OUTbit8
HomeSEL2
Select homming input source, Motor and Master encoders latch source.
HomeSEL2
OUTbit8
HomeSEL1
OUTbit4
StatusBit5
INbit0
StatusBit6
INbit1
Motor encoder latch
source
Master encoder latch
source
0
0
Limit1
Limit2/SingleLIMIT
Motor Encoder phase Z
Master Encoder phase Z
0
1
HomeIN
Input10
1
0
HomeIN
Input10
Input10 (change)
1
1
HomeIN
Input11
Input11 (change)
OUTbit9 to 11
N.A.
Reserved – clear to ‘0’
OUTbit12
MODEbitA
See Mode tables.
OUTbit13
MODEbitB
OUTbit14
MODEbitC
OUTbit15
MODEbitD
OUTbit16
FAULT
CN8pin9 FAULT output mode
OUTbit17 to 19
N.A.
Reserved – clear to ‘0’