background image

Logitek Electronic Systems, Inc. warrants its pro-

fessional equipment (excluding Logitek Software,
which is covered by a separate warranty) against de-
fects in materials and workmanship for two years pur-
suant to the following terms and conditions. The
warranty extends to the original purchaser only.

LOGITEK will repair or replace, at its option, at its

factory without charge professional equipment if a de-
fect in materials or workmanship develops during the
first two years following purchase, when the equip-
ment is returned to the factory or LOGITEK authorized
service centers freight prepaid with a description of
the nature of the failure. No reimbursements can be
made for repair charges that are not factory autho-
rized. After repair or replacement, LOGITEK will re-
turn the equipment to the purchaser freight prepaid.

In the event that any part of this professional equip-

ment becomes defective during the first two years fol-
lowing purchase, and purchaser wishes to attempt
repair, purchaser may obtain a replacement part by
notifying LOGITEK of the part of the equipment which
has failed. LOGITEK will thereafter ship a replace-
ment part, freight prepaid. LOGITEK may require the
purchaser to return the defective part to LOGITEK
freight prepaid as a condition of such replacement, ei-
ther before or after LOGITEK ships the replacement
part. LOGITEK shall not be responsible for any other
c h a r g e s o r l i a b i l i t i e s a s s o c i a t e d w i t h p u r-
chaser--made repairs.

No part or equipment shall be considered defective

if it fails to operate due to exposure to extreme temper-
atures or excessive moisture in the atmosphere.

Light bulbs, batteries, potentiometers or other

equipment not manufactured by Seller shall carry only
the warranty, if any, of the original equipment manu-
facturer in effect at the time of shipment of this order;
and Seller’s obligation under this warranty shall be
limited to such adjustment as Seller may obtain from
the original manufacturer.

This limited warranty is void if equipment is modi-

fied or repaired without authorization; subjected to
misuse, abuse, accident, water damage or other ne-

glect; or has had its serial number defaced or
removed.

No obligation is assumed by LOGITEK to update

previously manufactured equipment. Specifications
are subject to change without notice. EXCEPT AS
SPECIFICALLY PROVIDED HEREIN
LOGITEK
MAKES NO WARRANTY, REPRESENTATION,
PROMISE, OR GUARANTEE, EITHER EXPRESS
OR IMPLIED, STATUTORY OR OTHERWISE, WITH
RESPECT TO THE EQUIPMENT, USER DOCUMEN-
TATION OR RELATED TECHNICAL SUPPORT, IN-
CLUDING THEIR QUALITY, PERFORMANCE,
MERCHANTABILITY OR FITNESS FOR A PARTIC-
ULAR PURPOSE. IN NO EVENT WILL LOGITEK BE
LIABLE FOR INDIRECT, SPECIAL, INCIDENTAL,
TORT, ECONOMIC, COVER, OR CONSEQUENTIAL
DAMAGES ARISING OUT OF THE USE OF OR IN-
ABILITY TO USE LOGITEK PRODUCTS, EQUIP-
MENT, OR SERVICES,

INCLUDING, WITHOUT

LIMITATION, DAMAGES OR COSTS RELATING TO
THE LOSS OF PROFITS, BUSINESS, GOODWILL,
DATA OR COMPUTER PROGRAMS, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAM-
AGES. IN NO CASE SHALL LOGITEK ‘S LIABILITY
FOR MONEY DAMAGES EXCEED THE AMOUNT
PAID BY YOU FOR THE LOGITEK EQUIPMENT
OUT OF WHICH SUCH CLAIM AROSE.

THE

FOREGOING LIMITATIONS SHALL NOT APPLY TO
CLAIMS RELATING TO DEATH OR PERSONAL IN-
JURY WHICH ARISE OUT OF PRODUCTS DEEMED
TO BE CONSUMER GOODS UNDER APPLICABLE
LAW
.

Some states or provinces do not allow the exclu-

sion or limitation of implied warranties or limitation of
liability for incidental or consequential damages, so
the above exclusion or limitation may not apply to you.

The warranty and remedies set forth herein are ex-

clusive and in lieu of all others, oral or written, express
or implied. No Logitek dealer, distributor, agent, or
employee is authorized to make any modification or
addition to this warranty.

Page 20

** Bright-VU Instruction Manual **

TWO YEAR LIMITED WARRANTY

Logitek

Summary of Contents for BRIGHT-VU

Page 1: ...l B r i g h t V U 3 5 3 0 2 5 2 0 1 5 1 0 7 5 3 2 1 0 1 2 3 6 9 1 2 1 5 3 5 3 0 2 5 2 0 1 5 1 0 7 5 3 2 1 0 1 2 3 6 9 1 2 1 5 1 8 1 8 3 5 3 0 2 5 2 0 1 5 1 0 7 5 3 2 1 0 1 2 3 6 9 1 2 1 5 3 5 3 0 2 5...

Page 2: ...itek Electronic Systems Inc and is protected by United States copyright laws and international treaty provisions Logitek grants to you the right to use one copy of the embedded soft ware in each Brigh...

Page 3: ...TRUCTIONS 3 1 Bargraph Description 6 3 2 Display Ballistics 6 3 3 Using Alignment Tones 6 3 4 User Maintenance 6 3 5 Resetting the Program 6 SECTION 4 SERVICING 4 1 General Information 7 4 2 Fuse 7 4...

Page 4: ...ed Loop through 2200 Ohm balanced Termination transformer balanced Connector Female 3 pin XLR IN Male 3 pin XLR OUT AC Line Input Voltage 50 60 Hz 105 129 VAC or switch settable 220 240 VAC Power Requ...

Page 5: ...ected via a slide switch located next to the power transformer in side the unit To gain access to the voltage select switch remove the enclosure top cover The switch is located adjacent to the large p...

Page 6: ...iggered by several selectable fault conditions The relay contacts are brought out on the rear panel terminal block The alarm function is controlled by an eight position DIP switch located on the DSP c...

Page 7: ...verage and peak value of a sine wave The size of the VU to PPM difference is a function of signal wave shape and the only signal that has the same VU and PPM reading is a square wave 3 4 User Maintena...

Page 8: ...e risk of static electricity Store such circuits on conductive foam or in anti static containers Do NOT store on styrofoam or other plastic sheets Improper handling may damage these devices 4 4 Access...

Page 9: ...nes are current controlled and con nected to the LED anodes Digit lines connect to the LED cathodes Scanning is accomplished by taking each digit line low one at a time and sourcing current from the s...

Page 10: ...o data is sent synchronously data clock frame sync to the DSP in 64 bit strings via connector P3 The reset sig nal from the DSP control card is also connected to the ADC The DSP activates the reset on...

Page 11: ...10 153 P3 3 pin large header locking PN MLSS156 3A P4 3 pin header PN MFSS100 3A P5 6 10 pin dual row header PN 051 010 153 4 pcs 10 pin dual row socket PN 050 010 455 1 pc 3 pin large socket PN CE156...

Page 12: ...8 50K multi turn trim MP CT9X503 R9 10 300 1 pc Circuit card LG 271A Bright VU Analog Input 5 3 Digital Input Card Capacitors C1 047uf 50V CE CW 20C473K C2 4 1uf 50V SMD ceramic NC NMC1206Z5U104M50T...

Page 13: ...ver MM MAX7219CWG Resistors R1 10K Switches SW1 Slide SPDT CK TS01 C K E 1 pc Circuit card LG 273A Bright VU Display 5 5 Power Supply Capacitors C1 6800uf 35V electrolytic IL 688LBA035M2CD C2 1uf 50V...

Page 14: ...E103MATMA C23 1 uf 50V ceramic SMD NC NMC1206Z5U104M50T C24 25 470pf 100V ceramic SMD AV 12061A471JATMA C26 1 uf 50V Z5U SMD 1206 NC NMC1206Z5U104M50T Diodes D1 2 5 4V zener GI 1N4734A Integrated Circ...

Page 15: ...le CA HP Hewlett Packard Opto electronics Div Santa Clara CA IL Illinois Capacitor Lincolnwood IL LF Littlefuse Des Plaines IL LG Logitek Circuit cards Houston TX LT Linear Technologies Milpitas CA MM...

Page 16: ...SECTION 7 DIAGRAMS Page 16 Bright VU Instruction Manual...

Page 17: ...Bright VU Instruction Manual Page 17...

Page 18: ...Page 18 Bright VU Instruction Manual...

Page 19: ...Bright VU Instruction Manual Page 19...

Page 20: ...his order and Seller s obligation under this warranty shall be limited to such adjustment as Seller may obtain from the original manufacturer This limited warranty is void if equipment is modi fied or...