Install Option 2
This install option is similar to
Install Option 1
but for situations where the cable can only be fed in
from the side. However, rather than using the
Wall-Mounted
Base
, we will be using the
Ceiling-
Mounted Base
with the spring mounts removed.
1)
Remove the spring mounts from the
Ceiling-Mounted Base
and place on the wall to mark off
the drill holes.
2)
Drill the holes (5mm) and insert the wall plugs.
3)
Screw in the base to the wall, feeding the mains cable through the side, as shown.
4)
Connect the main cables to the
Smart Gas Detector
connection points and attach the device
to the base by lining up the slots on the
Smart Gas Detector
to the hooks on the base. Turn
clockwise to lock them together. Make sure the arrow label on the front of the device is
pointing upwards.
5)
Switch on the main supply. Installation is now complete.
Once the hardware installation is complete, you will need to follow the instructions in
Adding the
Device to the Smart Home Network
along with the
Logika Smart Mobile App
user manual to add
the device to the system.
You can then set up a
Housekeeper (Linkage) Task
to listen for an alarm condition and either sound a
Smart
Sound Warner
device and/or turn off the gas using a
Smart Valve Manipulator
.