When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow
the step below,
• Turn the gas tap to the MAX position and ignite
• Set the gas tap to the MIN flame position then turn the control from MIN to MAX several times.
If the flame is unstable or is extinguished follow the procedure below.
Pressure Testing
1. Remove the left hand pan support and front left burner cap and crown.
2. Fit manometer tube over the injector.
3. Turn on the burner gas supply and ignite all the other burners.
4. Turn off the burner supplies.
Check the Hob After Installation & Before Using
• If the appliance is to be installed above a cupboard or drawer it is absolutely essential that you
place a separating board between the base of the appliance and the drawer unit.
• This must be fixed in place 60 mm below the hob to prevent accidental contact with the bottom of
the hob which may be hot.
Attaching the fixing brackets
Your hob is supplied with 4 fixing brackets and 4 screws. You can attach the fixing brackets to any of the fixing
positions. If you worktop is not thick enough for the fixing bracket to make contact with add a separate piece of
wood (as shown below) to make up the thickness. Be careful not to over tighten the screws.
Do NOT over tighten the screws
Add an extra piece of wood to make the worktop thicker
if necessary.
LGHOBX16_IB.indd 21