24
Installation
• The cooker must be installed by a competent and Gas Safe Registered Engineer (in the UK) and in compliance
with local safety and building regulation safety standards.
• The cooker may be located in a kitchen, a kitchen/diner or bed-sitting room in accordance with the latest
editions of BS6172, BS5440-2 and BS6891, but not in a room containing a bath or shower. Please refer to the
local legislation/regulations to ensure location is permitted.
• If the cooker is installed adjacent to furniture which is higher than the gas hob, a gap of at least 100 mm must
be left between the side of the cooker and the furniture unless non-combustible materials (ceramic tiles, metal
backsplash etc.) are used which then allows this distance to be reduced to 20 mm.
• Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the
adjustment of the appliance are compatible. The adjustment conditions for this appliance are stated on the
label (or data plate).
• The furniture walls adjacent to the cooker must be made of heat resistant material (check with your furniture
supplier). The veneered synthetic material and the glue used must be resistant to a temperature of 100°C in
order to avoid ungluing or deformations.
• Flammable materials such as curtains, wood, wallpaper etc. must not be fitted immediately behind the
appliance or within 500 mm of the sides.
• Do not place next to a refrigerator.
• This cooker must NOT be placed on a pedestal or base.
• It is essential that the cooker is positioned as stated or freestanding ensuring the distances to flammable
materials etc. are still observed.
• Any cooker hoods must be installed according to the requirements of the cooker hood instruction/installation
manual but no less than 650 mm.
• Any cupboards placed directly above the cooker must be no less than 700 mm.
600 mm
420 mm
700 mm
X
Cupboard
600 mm
420 mm
650 mm
X
Cupboard
Cooker Hood
* All images are for indication only; please refer to your individual unit for actual item.
For all dimensions marked “X”, please
refer to the information below:
X : 100mm for combustible materials
20mm for non-combustible materials.
Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 24
Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 24
14/12/2020 16:07
14/12/2020 16:07