30
Table for the Choice of the Injectors
Burner Injector Values
According To The Gas Type
LPG
Natural Gas
G 30/31
28-30/37 mBar
G 20
20 mBar
• All intervention regarding installation maintenance and conversion of the appliance must be
fulfilled with original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
Large Burner (Fast)
Injector
mm
0.850
1.150
Gas Flow
(15°C and 1013mbar)
218.13 gr/h
276.00 lt/h
Power
kW
3.000
2.900
Standard Burner
Injector
mm
0.650
0.970
Gas Flow
(15°C and 1013mbar)
127.25 gr/h
166.66 lt/h
Power
kW
1.750
1.750
Small Burner (Simmer)
Injector
mm
0.500
0.720
Gas Flow
(15°C and 1013mbar)
72.71 gr/h
95.24 lt/h
Power
kW
1.000
1.000
Grill Burner
Injector
mm
0.690
1.100
Gas Flow
(15°C and 1013mbar)
152.70 gr/h
209.50 lt/h
Power
kW
2.100
2.200
Main Oven Burner
Injector
mm
0.750
1.150
Gas Flow
(15°C and 1013mbar)
174.50 gr/h
228.60 lt/h
Power
kW
2.400
2.400
Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 30
Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 30
14/12/2020 16:08
14/12/2020 16:08