DYNAMIC MOTION SYSTEM - SYSTEM MANUAL // PAGE 28
9.2 SYSTEM INFORMATION
9.2.1 DMUI-TOUCH-B-UD / DMUI-EASY2MOVE
When a DMUI-TOUCH-B-UD or DMUI-EASY2move Handset is installed alongside the DYNAMIC MOTION
system, system information is communicated via flashes of the LED Signal Light. Possible signals are as
follows:
Signal
Message
Required Actions
No Light
System operating normally
Operate the DM System as normal.
System not connected
properly
See Chapter 4 for connection instructions.
Red Light Blinking
System Error Warning
Release all Keys and wait for 5 seconds. Then,
try to repeat the action again.
Disconnect all components from the Power
Hub.
Disconnect the Power Hub from the Mains.
Check the Power Hub for overheating. Let cool
if necessary.
Check all cable connections and reconnect the
system.
If problem persists:
Perform a Position Reset Procedure (Chapter
4.7).
Contact LOGICDATA
Green Light Blinking
System Start-up
Wait until the LED has stopped blinking to
continue.
Do not press any buttons.
Reset in Progress
Duty Cycle Exceeded
Collision Detected (ISP)
Remove the obstruction from the Table System.
Remove unnecessary loads from the Table Top
Operate the DM System as normal.
Green Light Flashing
Rapidly
Position Reset Required.
Perform a Position Reset Procedure (Chapter
4.7).
NOTICE
Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA