background image

DMD660 - OPERATING MANUAL // PAGE 12

6  PRE-ASSEMBLY

Chapters 6, 7, 8, and 9 of this Operating Manual describe the process of installing the DMD660 into the 
Height-Adjustable Column. You must read the documentation for each part of the system (User Interface, 
Power Hub, etc.) for that product’s mounting instructions, and the System Manual for instructions on con-
necting the system. The processes shown in Chapters 7, 8, and 9 assume the DMD660 is to be installed in a 
Height-Adjustable Column in which the Top Plate can be removed (i.e. it is not permanently connected to 
the Tube closest to the Table Top). Contact LOGICDATA for instructions and safety advice on mounting the 
Actuator into other types of Height-Adjustable Columns.

6.1  SAFETY DURING ASSEMBLY

CAUTION

Risk of minor or moderate injury through improper handling

Improper handling of the product during assembly may lead to minor or moderate in-

jury through cutting, pinching, and crushing.

•  Avoid contact with sharp edges

•  Ensure assembly complies with the generally accepted standards and guidelines of 

electrical engineering and furniture manufacturing

•  Read all instructions and safety advice carefully 

CAUTION

Risk of minor or moderate injury through tripping

During assembly and operation, poorly routed Cables may become a trip hazard. 

Tripping over Cables may lead to minor or moderate injury.

•  Ensure that Cables are routed properly to avoid trip hazards

•  Be careful not to trip over Cables when assembling the DMD660

NOTICE

Ensure proper ESD handling during assembly. Damage that can be attributed to electro-

static discharge will void warranty claims.

NOTICE

To avoid damage to the product, measure the dimensions of the DMD660 before assem-

bly. Use a gauge or other suitable measuring equipment to do this.

NOTICE

Before assembly, all parts must be acclimatised to the ambient conditions.

NOTICE

Ensure the Height-Adjustable Column is of a sufficient length. The DMD660 must 

reach its final position before the Column is fully extended.

NOTICE

Non-standard Spindle settings may only be applied with approval from LOGICDATA.

NOTICE

Do not lift the DMD660 by its cable. This will cause irreperable damage to the product. 

INFO

Perform a product risk assessment so that you can respond to potential residual haz-

ards. Assembly instructions must be included in your end user Operating Manual.

Summary of Contents for DMD660

Page 1: ...MANUAL Document Version 1 0 October 2018 DMD660...

Page 2: ...0 October 2018 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462...

Page 3: ...xplanation of symbols and signal words 7 2 6 Liability 7 2 7 Residual risks 8 2 8 Skilled Persons 9 2 9 Notes for Resellers 9 3 Scope of delivery 10 4 Unpackaging 10 5 Product 11 5 1 Actuator Dimensio...

Page 4: ...mpleting Assembly 20 9 Assembly End Points 21 9 1 Step 1 Attaching the Motor End 21 9 1 1 Required Components 21 9 1 2 Process 21 9 2 Step 2 Attaching the Spindle End 22 9 2 1 Required Components 22 9...

Page 5: ...d full payment of the product all text and images in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user documentation for H...

Page 6: ...by Resellers in a Height Adjustable Column for electrically Height Adjustable Tables It is controlled by an integrated Control Unit It is intended for indoor use only The system may only be installed...

Page 7: ...vice Protection Class III Protection Class III devices may only be connected to SELV or PELV power sources INFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products compl...

Page 8: ...DMD660 is not connected to the Power Unit during assembly Do not convert or modify the DMD660 in any way Do not immerse the DMD660 or its components in liquid Clean only with a dry or slightly damp c...

Page 9: ...risks and avoid hazards Has knowledge of the specialist standards applicable to the product Has the expertise to test assess and manage electrical and mechatronic products and systems in accordance wi...

Page 10: ...ovided by the Reseller unless otherwise stated by LOGICDATA 4 UNPACKAGING NOTICE Ensure proper ESD handling during unpackaging Damage that can be attributed to electrostatic discharge will void warran...

Page 11: ...nstallation variant Thick Tube Down 6 Spindle End Attachment Point 5 1 ACTUATOR DIMENSIONS Fig 1 shows the dimensions of the DMD660 in its reset position installation position and extended posi tion F...

Page 12: ...eering and furniture manufacturing Read all instructions and safety advice carefully CAUTION Risk of minor or moderate injury through tripping During assembly and operation poorly routed Cables may be...

Page 13: ...Thick Tube Down Height Adjustable Columns go to Chapter 8 Fig 2 Thick Tube Up left and Thick Tube Down right in their retracted positions NOTICE In both installation variants the inner diameter of the...

Page 14: ...le Tube of the Height Adjustable Column to move synchronously The distance between the Middle Tube and the Motor End is always the same as the distance between the Middle Tube and the Spindle End Fig...

Page 15: ...is position 1 Turn the Aluminium Tube counter clockwise until it reaches the end position 2 Turn the Tube in the opposite direction until it is 1 25 mm from the end position This is called the Install...

Page 16: ...justable Column skip this chapter and continue at Chapter 8 7 1 ATTACHING THE ADAPTER SLEEVE In Thick Tube Up Height Adjustable Columns an Adapter Sleeve is required to connect the Actuator to the Mid...

Page 17: ...d Ensure all flaps have been snapped into place 3 Slide the Fixing Ring along the Actuator and snap it into place at the top of the Adapter Sleeve This will fix the Adapter Sleeve into place 4 Rotate...

Page 18: ...ing the Actuator NOTICE The maximum pull force on the Middle Tube Adapter may not exceed 150N If this force is exceeded a functional reset cannot be guaranteed 7 2 1 REQUIRED COMPONENTS 1 DMD660 Actu...

Page 19: ...ddle Tube Adapter Fig 8 fixes the DMD660 to the Middle Tube of the Height Adjustable Column It is supplied by the Reseller Fig 8 Example of a Middle Tube Adapter Thick Tube Down The Middle Tube Adapte...

Page 20: ...te the Actuator s Nut Insert Fig 9 to minimize friction between the Middle Tube Adapter and the DMD660 Consult LOGICDATA for a list of recommended lubricants Fig 9 Lubricating the Nut Insert 5 Use a s...

Page 21: ...o mount the Top Plate Use a Torque Screwdriver to ensure the Screws are tightened to the recommended torque of 2 5 3 Nm 9 1 1 REQUIRED COMPONENTS 1 Mounting Screws and Rubber Washers Ordered separatel...

Page 22: ...TA for specifications Tool Torque Screwdriver INFO LOGICDATA provides specifications for the Bottom Plate only on request These in clude dimensions and tolerances as well as notes on material selectio...

Page 23: ...serious injury through electric shocks and other hazards Only use accessory parts produced or approved by LOGICDATA Only use replacement parts produced or approved by LOGICDATA Only allow Skilled Pers...

Page 24: ...rk 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 1525 Gezon Parkway SW Suite...

Reviews: