Signal Animator

 

(SAD-SBCA) 

Tomar semaphore motor, bulb-based & 
LED-based, common-anode position 
light signal instructions – IR version

 

 

Revised 2/8/13

 

 

Getting started 

Thank you for purchasing a

 Logic Rail Technologies

 product!  Please read all instructions prior to installing this board.  

 

The 

Signal Animator

 provides automatic operation of 3-color/aspect block 

signals  in  a  semi-prototypical  way.  An  Infrared  (IR)  emitter  and  detector 
are used for train detection. Detection is achieved when the IR beam from 
the emitter reflects off the underside of the train back down to the detector. 

Despite  the  use  of  infrared  components  you  could  still  encounter  false 
triggering  from  overhead  lighting.  This  is  usually  eliminated  with 
angled  sensor  mounting  and/or  proper  sensor  sensitivity  adjustment 
(page  4). 

 

This  version  of  the 

Signal  Animator

  must  be  powered  from 

either  a  7-9V  AC  or  9-12V  DC  power  source.  Do  NOT  exceed  these 
limits!

 Whenever the sensor is activated by any portion of a train the signal 

will turn red. Once the sensor is cleared the 

Signal Animator

 will delay (10 

or  30  seconds;  see  below)  and  then  change  the  signal  to  yellow.  After 
another delay the signal will be changed to green. 

 

 

 

These instructions cover the  version of the Signal  Animator that provides 3-aspect  signaling for Tomar  semaphore motors, 
bulb-based signals (including position light signals), and LED-based, common anode (positive) wired position light signals. 
The signal outputs are “active low” (~ 0 volts when on) and capable of handling 150mA per output.  

 

You  should  make  all  of  the  connections  to  the 

Signal  Animator

  before  applying  power  to  it.  You  can  mount  the 

Signal 

Animator

 anywhere it is convenient underneath your layout using the four mounting holes provided. The holes will accept  

#4 screws; do not enlarge the holes as damage to the circuit board can result and your warranty will be voided! 

 

Tomar Semaphore Motor Connections 

Connections between the Signal Animator and a Tomar Industries’ semaphore motor are illustrated below. The input voltage 
will affect the speed of the turnout motor. 

SAD-SBCA-IR

DLY

C

  

 Y

  

 R

  

 G

A

C

  

  

G
N

D

  

D

C

  

 +

5

V

  

 P

C

6

7

10

5

Tomar 

motor unit 

connector

Not used

 

Figure 1 – Tomar semaphore motor connections 