Parameter 5, Parameter size 4 bytes. LEDs colour indication.
This parameter specifies the colour levels for the red, green and blue colours in the 4 RGB LEDs. This parameter
is not used unless configuration parameter 4 is set to the value 2. The default configuration is a white light, where
red level value must be higher than the two other colours in order to get a white light.
Value
Description
Byte 1: Red colour level.
0 - 255
Specifies the level for the red colour. (Default is 255)
Byte 2: Green colour level.
0
–
255
Specifies the level for the green colour. (Default is 85)
Byte 3: Blue colour level.
0 - 255
Specifies the level for the blue colour. (Default is 85)
Byte 4: Not used.
0
This byte is not used and must be set to 0.
Parameter 6, Parameter size 2 bytes. Associations groups, transmission when included secure.
This parameter specifies if commands are transmitted as a secure message for each of the association groups.
This parameter is only used when the device is included in security mode (either S0 or S2).
Value
Description
0
All messages in all groups are sent as insecure.
1
Messages in association group 2 are sent as secure.
2
Messages in association group 3 are sent as secure.
4
Messages in association group 4 are sent as secure.
8
Messages in association group 5 are sent as secure.
16
Messages in association group 6 are sent as secure.
32
Messages in association group 7 are sent as secure.
64
Messages in association group 8 are sent as secure.
128
Messages in association group 9 are sent as secure.
255
All messages in all groups are sent as secure. (Default)