3. Display
Telemetry
•
Status
•
Address (CAN address for the telemetry device)
Service Timers
•
Timers 1-16 (each timer is listed separately)
–
Hours remaining
–
Reset
Tier 4 Control
•
Inhibit - OFF/ON (inhibit Regenerations)
•
Request Force (request a Force Regeneration; depending on conditions, ECU may not honor)
•
Status (database Viewer for Tier 4 related status messages from the ECU)
Database Viewer
3.9.2
Access Levels
The available menu items are dependent upon the current access level. The current access level is
shown in the upper right corner while in the menus. The CP640c supports up to three (3) independent
PINs that are configurable. The standard LOFA configuration has the following PINs settings:
•
User = 1000
•
Tech = 1111
•
Admin = 2222
•
Menu PIN Required = OFF
Elevate Access Level
When the panel is turned on, the access level reverts to the User level. To gain access to
Tech or Admin levels, use the Elevate Access Level menu
Configuration
System
PIN Settings
Elevate Access Level
.
The panel will prompt for a PIN input. User, Tech, or Admin level access will be granted based on
which PIN is entered. Example: If the Tech level PIN is entered, Tech level access will be granted
and similarly if Admin or User level PINs are entered. If the entered PIN does not match User, Tech,
or Admin, then ”Incorrect PIN” is displayed and the access level reverts to User.
LOFA document No. 463-3002-22