3. Display
Only active faults are displayed in the alarm list. Once a fault is corrected it
is automatically removed from the list. To view previously active faults press
the ”STORED” button.
3.8
Service Timers
The CP640c display provides sixteen (16) service timers to alert the operator of required maintenance.
The time interval for each timer can be adjusted in increments of ten (10) hours. A popup message
is displayed after the display self-test if a timer (or timers) has expired alerting the user that service
is required. The message is displayed on each power up until the elapsed timer is disabled or reset.
The service timers can have their respective names customized to monitor engine- and pump-related
parameters. All sixteen (16) service timers can be monitored via wireless telemetry.
3.9
Menus
The menu pages can be accessed by pressing and holding button 5. After one (1) second, the
top-level menu page will appear. From there the functions of the five display buttons change to allow
navigation and selecting and modifying parameters.
Button 1
Button 2
Button 3
Button 4
Button 5
Sroll Up
Scroll Down
[Intentionally
Blank]
Go into Selected
Submenu
Return to
Previous Menu
Decrement Value
Increment Value
or
or
Previous
Selection
Next Selection
The menus pages can also be accessed by pressing and holding the optional Rotary Control using
LOFA’s RotaryPlus™ technology:
•
Push and hold the rotary for one (1) second to open menus main page
•
Move down through the menu choices with clockwise rotations
Page 10
LOFA document No. 463-3002-22
Page 10