background image

First Startup Zenit

+

 

14

Sensing Head Display

 

A 1 

 

F 00

 

 

G 00

 

H 1

 

with 

 = class cut 

without 

 = channel cut

 

C 00 

 

D 00

 

with 

 = thin place 

without 

 = thick place

 

S 1 

 

R 1

 

 I 1 

 

O 1

 

with 

 = bright 

without 

 = dark

 

Nep

  

Joint

 

  

nep

 

Short

  

Joint 

  

short

 

Long

  

Joint 

  

long

 

Thin

  

Joint 

  

thin

 

with 

 = class cut 

without 

 = channel cut

 

flashing display indicates ALARM 

(selected no. of repetitions reached)

Sensing Head Display

Cut Type

 

Nep

 - unclassified  

Long

 - unclassified

 

Short

 - unclassified

   Thin

 - unclassified

 

Off Count

  

SFI / D

 

Short Off Count 

 

VCV

 

with 

 = minus 

without 

 = plus

  

Cluster 

nep 

Upper Yarn

 

Cluster

 

short 

Bunch

 

Cluster 

long

 

Cluster 

thin

 

F

 (foreign matter)   

F Cluster

 

with 

 = bright 

without 

 = dark

  

 

 

P

 (synthetics)

 

Zeroing

 

 

flashing display indicates ALARM 

(selected no. of repetitions reached)

Class Type

 

Yarn runs – Diameter difference  

_< 

+ / -

  10 %

 

Yarn runs – Diameter difference  

+

  10 %

 

Yarn runs – Diameter difference  

-

  10 %

 

Technical Alarm 

(alternating)

 

Cutter supply or coil failure 

(alternating)

 

Internal power supply failure TK 

(alternating)

 

No NTP signal 

(alternating)

 

Knife blocked 

(alternating)

 

Zeroing failed 

(alternating)

 

Spindle cycle timeout

 (alternating)

 

Class Alarm

 

Off Limit Alarm

 

IPI Alarm

 

Adjust

 

Doffing

 

Waiting for 

spindle communication

 

Waiting for 

central unit parameters

 

Spindle locked, group not started 

 

Reset

 

Update TK Firmware

 

Cut by spindle

 

Zeroing failed

 

Cut by user 

(Test / Reset button)

 

D brightness regulator out of limit

 

F brightness regulator out of limit

 

Adjust cut

 

Cut failed

 

Adjust failed

 

Configuration changed by LZE

 

Spindle power failure

Spindle

System Info

System Cuts

Technical Alarms

Textile Alarms

50320003 en

Summary of Contents for YARNMASTER ZENIT+

Page 1: ...YARNMASTER ZENIT 50338003 en V 5 9 x x 03 2019 First Startup Step by Step...

Page 2: ...omplete or partial reproduction and dissemination of this Instruction Manual to third parties even in form of extracts as well as the use and or disclosure of the contents are not allowed without the...

Page 3: ...2 External power supply 90 264 VAC Central unit LZE V Power supply unit 24 VDC Spindle adapter SA Loepfe 2 wire bus L2B Loepfe 2 wire bus L2B LAN connection crossover cable Sensing head cable Sensing...

Page 4: ...Description Power Sub D PSC Power supply 24 VDC Contact 1 24 VDC Contact 2 not connected Contact 3 0 VDC ATTENTION Only 24 VDC may be supplied to this connection Threaded connection Protective ground...

Page 5: ...ge Unsaved data are lost LED orange Tap 1 Sec Start LED becomes green LAN 1 RJ45 Dedicated connection for LZE V Faceless IP 192 168 1 200 Default Attention Mistakenly changing the LAN 1 IP address mig...

Page 6: ...quiring intervention 7 Data selection filter Dashboard Monitoring and Quality menus 8 Login access level 9 Language selection 10 Online help 11 Action buttons function buttons 12 Connection status Eth...

Page 7: ...ick Data export import Back Next Edit settings Confirm selection input Cancel selection input Undo input Copy article Start lot group Stop lot group Adjust groups spindles in production Reset monitori...

Page 8: ...5 Login 1 Tap Login button 3 Tap password input field 5 Confirm entry with 2 Select user Foreman Foreman login is required for all settings during initial start up 4 Enter Foreman password 12911291 2...

Page 9: ...Setup Date and Time 1 Activate the Edit mode by tapping 2 Enter date day 3 Enter time hour minutes seconds 4 Confirm each entry with 6 Set Date and Time 5 Save date and time with 6 Confirm pop up Sav...

Page 10: ...Module Bootloader and Firmware Versions The versions shown in the Master Module field and in the Spindles field must match the versions shown in the Firmware Archive field Perform the Firmware Update...

Page 11: ...Spindles Enter total number of winding units of machine Yarn Count Unit Select unit Nm Ne Tex Den Sensing Head Type Installed sensing head type D DF DFP Splice Check Length Use default setting Previou...

Page 12: ...respective group settings 3 Activate the edit mode by tapping Settings Group 4 First Spindle Last Spindle Enter spindle range first and last spindle of the group 5 Article Tap entry field and select...

Page 13: ...s displayed in column Status and Active in column Adjust 4 Start and monitor the respective number of pilot spindles individually The Ad display goes out for each pilot spindle when adjustment is term...

Page 14: ...ndicates ALARM selected no of repetitions reached Class Type Yarn runs Diameter difference _ 10 Yarn runs Diameter difference 10 Yarn runs Diameter difference 10 Technical Alarm alternating Cutter sup...

Page 15: ......

Page 16: ...Loepfe Brothers Ltd 8623 Wetzikon Switzerland Phone 41 43 488 11 11 Fax 41 43 488 11 00 info loepfe com www loepfe com Subject to technical modifications...

Reviews: