background image

w92320.09 

ENCLOSURE

 

Weight 

 

0.5 lbs (335gms)

 

Lid 

 

Clear PC/FR V0 and UV stabilised

 

Base 

 

Black PC V0 and UV stabilised

 

Breather   

Gortex fitted in base

 

Mounting   

4 external lugs

 

Fixings 

 

5mm (3/16

) not supplied

 

IP Rating   

IP55

 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
S = Standard. C = Customer configured (see 

Factory Settings

).

 

 

+  

 

 

Positive 

8-36V supply

 

-  

 

 

Negative  0 Volts

 

F1 to F16   

 

Outputs to F1 through F16

 

 

 

Master Output

 

STOP - 

 

 

STOP, when grounded shuts down the Receiver

 

S+ S- 

Master Secondary for Safety solenoid connections etc. 

 

ANT 

Blade connector for internal antenna

 

SMA 

Aerial connection for optional external antenna (internal antenna must be removed)

 

LK1 

Master Selection by Jumper (Parallel)

 

LK2 

Master Selection by Jumper (Continuous)

 

Factory Settings 

418/915MHz configured Parallel, 433.92MHz configured Continuous

 

RS232 

RS232 for Wired Remote and interface to access special programmes

 

 

 
 
 
 
 
 
 
 
 
 
 

92 Series 

92

320

 

BUILD SPECIFICATION TABLE FOR MODELS IN THIS RANGE 

Ident 

Legend 

Connection 

 

+ -  

Positive, Negative,  

 

M, F1, F2, F3 

Master F1, F2 and F3 

 

F4, F5, F6, F7 

F4, F5, F6 & F7 

 

F8, F9 & F10 

F8, F9 & F10 

 

F11, F12, F13, F14 

F11, F12, F13 & F14 

 

F15, F16, F17, F18 

F15, F16, F17, F18 

 

F19, F20 

F19, F20 

 

S+, S- 

Safety Solenoid S+ and S- 

 

STOP, 0Volts 

STOP connections 

 

ANT 

Internal Antenna 

 

  

SMA (external antenna) 

LK1 

LK1 

Master - Parallel 

LK2 

LK2 

Master - Continuous 

 

RS232 

RS232 

 

 

 

 

Number of Receivers 

 

Number of Transmitters 

Reviews: