5.
Operating the Unit, (continued)
Shutter ON Time Setting
The first parameter that can be changed is the amount of time that the shutter is open during
a cycle. The time can be increased or decreased using the
(+)
or
(-)
buttons. The shutter
open time can be set with the following limits:
Time Base
Min Time
Max Time
0.1 sec
.3 sec
24.9 sec
1.0 sec
25 sec
250 sec
The time base automatically changes at 25 seconds. If a user selects a time below the
minimum range the unit goes to
MANUAL
mode. In
MANUAL
mode the shutter is directly
operated by the footswitch. If the footswitch is pressed the shutter will open, closing as
soon as it is no longer pressed. Once this parameter is set press
ENTER
to continue.
Shutter OFF Time Setting
The next parameter that can be changed is the amount of time that the shutter is closed
during a cycle. The time can be increased or decreased using the
(+)
or
(-)
buttons. The
shutter close time can be set with the following limits:
Time Base
Min Time
Max Time
0.1 sec
.1 sec
24.9 sec
1.0 sec
25 sec
250 sec
The time base automatically changes at 25 seconds. Once this parameter is set press
ENTER
to continue.
Cycle Count
The next parameter that can be changed is the number of cycles that will run during a
single iteration. The number of cycles can be increased or decreased using the
(+)
or
(-)
buttons. The maximum number of cycles that can be run during a single iteration is 255.
Once this parameter is set press
ENTER
to continue.
To interrupt the cycle sequence when the shutter is operating, press the foot switch down
for approximately 2 seconds, (contact across pins 1 and 9 of XS-1).