3.
Technical Data
Energy Requirements
Input Voltage Ranges: 90 to 240 VAC
Input frequency Range: 50 to 60 Hz
Auxiliary Output Voltage: 24 volts DC, nominal
Main fuse located in power module in rear of unit: 4A T/250V, 5mm
Dimensions
Housing: Approximately 12 ½ inch W x 9 ¾ inch D x 5 ½ inch H
Weight: Approximately 7 pounds
UV Output Characteristics
Initial UV output: up to 15 W/sq.cm, typical. Exact output measurement is dependent
on the brand and calibration method of the meter used, as well as the condition and
straightness of the light guide.
0
1000
2000
3000
4000
200
300
400
500
600
700
800
Intensity (counts)
Wavelength (nm)
Summary of Contents for CL15 UV
Page 22: ......