background image

1.  Please Observe the Following

1

1.1 Emphasized Sections

Warning!

Refers to safety regulations and required safety measures that protect the operator or other 
persons from injury or danger to life.

Caution!

Emphasizes what must be done or avoided so that the Unit or other property is not damaged.

Notice:

Gives recommendations for better handling of the Unit during operation or adjustment as well as
for service activities.

1.2 For Your  Safety

For safe and successful operation of the Unit, read these instructions completely. If the
instructions are not observed, the manufacturer can assume no responsibility. Be sure to retain
this manual for future reference.

WARNING! 

Do not use the Unit to extract easily flammable or explosive gases.

WARNING! 

Do not use the Unit to extract corrosive substances.

WARNING! 

Do not expose the connecting cable to heat, oil, or sharp edges.

WARNING! 

Make sure the Unit stands stable and secure.

WARNING! 

Use only original equipment filters.

WARNING! 

Do not operate the Unit without filter inserts. Contaminants in the extracted air will damage 
the blower.

WARNING! 

Always disconnect the power supply before servicing the Unit.

WARNING! 

Never cover intake or exhaust openings.

WARNING! 

This system is equipped with automatic reset overload protection (thermal switch or overload
relay), which may cause the Unit to restart automatically. See page 4.

WARNING! 

Observe general safety regulations for the handling of chemicals such as Loctite

®

adhesives 

and sealants. Observe the manufacturer’s instructions as stated in the Material Safety Data 
Sheet (MSDS).

While under warranty, the Unit may be repaired only by an authorized Loctite service
representative.

1.3 Unpacking and Inspection

Carefully unpack the Loctite

®

Air Filtration System and examine the items contained in the carton.

Inspect the Unit for any damage that might have occurred in transit. If such damage has occurred,
notify the carrier immediately. Claims for damage must be made by the consignee to the carrier
and should be reported to the manufacturer.

Summary of Contents for 98276

Page 1: ...EQUIPMENT Operation Manual Loctite Air Filtration System Part Number 98276 ...

Page 2: ...ENTS AND CONSTRUCTION 2 2 2 THEORY OF OPERATION 3 2 3 FILTERING METHOD 3 4 2 4 THERMAL OVERLOAD PROTECTION 4 3 TECHNICAL DATA 5 4 INSTALLATION 5 4 1 INSTALLATION AND CONNECTION 5 5 MAINTENANCE AND CLEANING 6 7 5 1 FILTER UNIT 6 5 2 FILTER REPLACEMENT 6 7 6 TROUBLESHOOTING 7 7 SPARE PARTS AND ACCESSORIES 8 7 1 REPLACEMENT FILTERS 8 7 2 ACCESSORIES EXHAUST ARM KIT 8 7 3 ACCESSORIES EXHAUST CABINET K...

Page 3: ... secure WARNING Use only original equipment filters WARNING Do not operate the Unit without filter inserts Contaminants in the extracted air will damage the blower WARNING Always disconnect the power supply before servicing the Unit WARNING Never cover intake or exhaust openings WARNING This system is equipped with automatic reset overload protection thermal switch or overload relay which may caus...

Page 4: ... differential pressure gauge indicates the filter status 2 Description 2 1 Operating Elements and Construction Main Switch Foot Switch A foot switch is used to turn the filter unit on and off This switch needs to be located as far away from the filter unit as possible Filter Monitor Differential Pressure Gauge Filter Monitor The differential pressure gauge monitors the filter condition by measurin...

Page 5: ...od The contaminated air is drawn into the filter unit and passes through a combination of filters Filtration is accomplished in three stages The pleated prefilter removes coarse particles such as dust The gas phase filter absorbs gases and odors The efficiency and lifetime of the gas phase filter depends on a range of variables which are among others flow rate temperature humidity concentration le...

Page 6: ...austed air for contamination The lifetime is measured in operating hours until breakthrough occurs An optional way is a laboratory evaluation of the spent gas phase filter media after a certain time period For further information contact our customer service department 2 4 Thermal Overload Protection The filter unit motor is equipped with factory installed automatic thermal overload protection In ...

Page 7: ...metal carbon filter tray Fill the carbon tray with activated carbon The activated carbon is supplied in a separate bag Check to insure afterfilter mat is properly seated Install carbon tray into Unit Install pleated prefilter Install the Unit s top cover and secure the four latches Attach a flexible hose to the air inlet port s on the lid using hose clamps If the sum of the ports are not being use...

Page 8: ...pty the filter tray by pouring the saturated filter media into a waste container Dispose of carbon tray filter mat Caution Used filter media may contain toxic or flammable substances Observe relevant codes for safety and local hazard s material disposal Install the white mat on the bottom of the metal carbon filter tray Fill the carbon tray with activated carbon The activated carbon is supplied in...

Page 9: ...ug The Loctite Air Filtration System is to be turned on Do not operate the filter system without filters installed This may overload the electric motor Caution Do not clean the filters Cleaning the filters by batting or using compressed air will destroy the filter Always use a new replacement filter 7 5 Maintenance and Cleaning continued 6 Troubleshooting Type of Malfunction Possible Causes Soluti...

Page 10: ... Cover Latches 4 Pack 1 987357 2 5 Vent Plug 2 Pack 1 987358 4 Vent Cap 2 Pack 7 2 Accessories Exhaust Arm Kit 1 987351 Omni Flex Exhaust Arm ESD 2 5 dia 24 long reach includes rectangular nozzle universal mounting plate connection hose and wall mounting kit 1 987388 Connection Hose 2 5 diameter 8 long with hose clamps 1 987390 Mounting Kit consists of mounting angle and C clamps 7 3 Accessories E...

Page 11: ...cts are available from Henkel Loctite the use of products parts or attachments which are not manufactured by Henkel Loctite no claim shall be allowed No Products shall be returned to Henkel Loctite for any reason without prior written approval from Henkel Loctite Products shall be returned freight prepaid in accordance with instructions from Henkel Loctite NO WARRANTY IS EXTENDED TO ANY EQUIPMENT ...

Page 12: ...k Crossing Rocky Hill CT 06067 3910 Henkel Loctite Automotive Technology Center 2455 Featherstone Road Auburn Hills Michigan 48326 Henkel Loctite Canada Inc 2225 Meadowpine Boulevard Mississauga Ontario L5N 7P2 Henkel Ltda Brazil Av Prof Vernon Krieble 91 06690 11 Itapevi São Paulo Brazil Henkel Mexicana S A de C V Calzada de la Viga s n Fracc Los Laureles Loc Tulpetlac C P 55090 Ecatepac de Morel...

Reviews: