8 Troubleshooting
This error is displayed after the exposure
has been started, but the shutter does not
open.
– No compressed air.
– Air throttle (advance forward/shutter
closed) of pneumatic cylinder closed.
Check compressed air connections
To open closed air throttle, turn counter clockwise approx. 1 turn. Correct setting if
error message is repeated.
Measured value below UV minimum
setting.
Replace bulb, See section 8.3.
This error will be displayed if the cure
cycle is interrupted by the user,
e.g. in time-controlled mode by triggering
a 2
nd
start signal;
but not by pressing the Emergency stop
button.
Other reasons:
In
continuous
mode:
– Maximum exposure time 900 s (15 min) exceeded.
8.2 General Errors and their Corrective Actions
Malfunction
Possible Cause
Corrective Action
Equipment does
not work
– No power.
– Power switch not depressed.
– Power fuses defective.
– Power cord defective.
Check supply voltage.
Press power switch.
Check fuse.
Replace power cord.
Excessive wear
of the bulb when
operating at
500W
– Bulb is operated only at 500W.
Operate the bulb daily at 1000 W
for about 15 minutes..