8
Description - Typical System Set-Up
2
5
Button
Button for switching the measuring units for the dispensing pressure in the digital display.
After each pressing of button
, the indication of the selected dispensing pressure in the digital
display changes to the other measuring unit [bar or psi] with the corresponding value.
6
Button
Button for switching from time controlled mode to
cont
inuous mode.
The lighting of the LED in button
indicates continuous mode (see Section 5.2.2.2).
By pressing button
, the indication of the dispensing time in the digital display is set to 0.00 s and
blinks. During dispensing, the elapsed dispensing time is indicated in the digital display beginning each
time with 0.00 s. The last dispensing time remains displayed until the next start.
– Switch back to time controlled mode
without storage
of the dispensing time by repeated pressing
of button
. The LED in button
extinguishes. In the digital display, the dispensing time
previously stored for the time controlled mode reappears.
– Switch back to time controlled mode
with storage
of the dispensing time by pressing
button
. The LED in button
extinguishes. The indicated dispensing time is stored and the
display stops blinking.
7
Vacuum Control
Control for pulling a vacuum in the syringe.
With this vacuum, the product is sucked back during dispensing pauses to prevent dripping.
– Turning in the counter clockwise direction: The vacuum action is increased until the dripping stops.
– Turning in the clockwise direction:
The vacuum action is reduced.
8
Pneumatic Connection for Syringes (Outlet)
9
Precision Pressure Regulator
Precision regulator for adjusting the dispensing pressure.
By turning the regulator knob, the dispensing pressure is adjusted in the range from 0.00 to 7.00 bar
(0.00 to 100 psi).
If the error message “
P
Pr
re
es
ss
s.
.
0
0.
.8
83
3
N
NO
OK
K
” appears with beeping, the dispensing pressure was changed
more than ± 10 %. The value
0
0.
.8
83
3
[bar/psi] is only an example for the displayed dispensing pressure
(see Chapter 7).
By pressing button
, the indicated dispensing pressure is stored as the new comparison value for
automatic pressure monitoring. The error message and beeping are eliminated.
10
Power Switch I/O (ON/OFF)
CONT
CONT
CONT
CONT
CONT
CONT
bar
psi
bar
psi