11
3.1
Energy Requirements
3.1.1
Electrics
Power supply
90 – 260 VAC; 47 – 63 Hz
Power consumption
Approx. 40 W
Power protection
Glass tube, fine wire fuse, 2 AM
Internal control voltages
5 VDC; 12 VDC; 24 VDC
3.1.2
Pneumatics
Pneumatic supply
min. 2 bar (29 psi); max. 12 bar (174 psi)
Quality
Filtered 10 µm, oil-free, non-condensing
If the required quality is not achieved,
install a Loctite
®
brand filter regulator.
Accessory Order No. 985397
Regulation range of the pressure regulator
0.00 – 7.00 bar (0.00 – 100 psi)
Pressure indication
0.00 – 7.00 bar (0.00 – 100 psi)
3.2
Connections and Dimensions
Power connection
cold appliance coupl. IEC 320 acc. to VDE 0625
Pneumatic hose size
Internal dia. - 4 mm; external dia. - 6 mm
Dimensions
W x H x D: 145 x 230 x 260 mm
3.3
Other Data
Protection grade
IP 33 acc. to VDE 0470, Part 1 / EN 60529-1991
Operating temperature
+10 °C to +40 °C (+50 °F to +104 °F)
Storage temperature
-10 °C to +60 °C (+14 °F to +140 °F)
Weight
3.0 kg
Continuous sound pressure level
< 65 dB(A)
+0,05
–0,10
Technical Data
3