background image

    
 3.2 Curing Procedure 

-

 

Having determined the irradiance necessary to cure the adhesive, fixture the 
reflector housing over the work surface at the proper height. The M5 threaded 
inserts located in the top of the reflector housing are intended for this purpose. 

-

 

When the cure cycle is initiated from the controller, the LED’s will light 
immediately.  

-

 

Place the part/adhesive assembly under the reflector housing so that the center of 
the bond area is under the center of the housing for the required exposure period.  
If the unit is mounted over a conveyor, the parts must be passed under the center 
of the reflector housing for the best results. 

 
 
4 Maintenance 
 

4.1 Protective Glass 

 Notice: 

It is recommended that the protective glass in the reflector housing be regularly inspected 
for cleanliness.  Contaminants will adversely affect the curing process by reducing the 
transmission of visible light to the adhesive.  Remove any contaminants by carefully 
wiping the glass surface with a soft, clean cloth and isopropyl alcohol. 

 
 
5 Trouble Shooting 
 

Condition

Possible Cause

Correction

None of the LED’s light when 
the cycle is initiated.

 

Damaged or improperly 
installed power cable. 

Check both ends of cable are 
secure. 

The LED’s go out after 
operating for a short time. 

Thermal overload. 

Check LED array cooling fan 
operation. 

Some of the LED’s do not light. 

Damaged LED power cable.

Replace cable. 

The product takes increasingly 
longer to cure. 

Contamination on 
protective glass. 

Clean off glass with clean soft 
cloth and isopropyl alcohol. 

 
 
 
 

 
 
 
 

 

 

 

 

 
 
 

Summary of Contents for 1167593

Page 1: ...EQUIPMENT Operation Manual Loctite LED Flood System Part Numbers 1167582 UVA nm Array 1167593 405 nm Array 1167589 Indigo Array ...

Page 2: ...ty Be sure to retain this manual for future reference WARNING Do not look directly into the LED reflector array WARNING Damage to the power cord power supply housing or LED housing can result in contact with live electrical parts Check the power cord and housings before each use If the power cord or units are damaged do not operate WARNING The unit must be repaired only by a Loctite authorized ser...

Page 3: ...th Loctite Indigo product line The curing process begins when the adhesive is placed under the LED s The two primary variables that control the curing process are the time of exposure and the strength of the light irradiance For a given irradiance the exposure time required to fully cure the adhesive depends primarily on the properties of the adhesive and the optical properties of the substrate th...

Page 4: ...rotective Glass Notice It is recommended that the protective glass in the reflector housing be regularly inspected for cleanliness Contaminants will adversely affect the curing process by reducing the transmission of visible light to the adhesive Remove any contaminants by carefully wiping the glass surface with a soft clean cloth and isopropyl alcohol 5 Trouble Shooting Condition Possible Cause C...

Page 5: ... or call Henkel Corp at USA 1 860 571 5174 Germany 49 89 9268 0 Singapore 65 6266 0100 Label P N 988341 UVA LED Flood System S N XXXXX Item 1167582 LED Flood System RoHS Compliant Label P N 8900605 Important Do not restrict cooling air Allow at least six inches clearance from exhaust fan port and heat sink intake ...

Page 6: ...oducts parts or attachments for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason without prior written approval from Henkel Products shall be returned freight prepaid in accordance with instructions from Henkel NO WARRANTY IS EX...

Page 7: ... P 55090 Ecatepac de Morelos Edo de México Henkel Corporation Automotive Metals HQ 32100 Stephenson Hwy Madison Heights MI 48071 Henkel Ltda Rua Karl Huller 136 Jd Canhema 09941 410 Diadema SP Brazil www loctite com Loctite is a trademark of Henkel Corporation U S A Copyright 2004 Henkel Corporation All rights reserved Data in this operation manual is subject to change without notice Manual P N 89...