![LOCO COOKERS LCTFKESB30 Owner'S Manual & Assembly Instructions Download Page 17](http://html1.mh-extra.com/html/loco-cookers/lctfkesb30/lctfkesb30_owners-manual-and-assembly-instructions_1933677017.webp)
17
lococookers.com
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Burner will not light.
Bad connection between the
regulator and LP tank.
Make sure the regulator coupling nut is
fully tightened on the LP tank valve.
The LP tank is empty.
Re
fi
ll LP tank at an authorized dealer
or purchase new
fi
lled LP tank.
Ignition button was not pushed
and held.
Press and hold the ignition button for
30 seconds while lighting burner.
Battery not installed correctly.
Make sure the
+
and
–
ends of the
battery are oriented properly. The
+
end should be toward the battery cap.
Weak or dead battery.
Replace with new alkaline AAA battery.
Battery cap not installed
correctly.
Unscrew battery cap and reinstall.
Make sure threads are aligned and
engaged fully.
Burner does not stay lit. Excessive wind conditions.
When appliance is cool, move
appliance to di
ff
erent location where
high wind is not a factor. Relight
burner.
Smart Temp heat sensor has
extinguished
fl
ame due to
excessive oil temperature.
Turn the regulator control valve and
the LP tank valve OFF. Allow oil to cool
and relight burner.
Oil does not reach
desired cooking
temperature.
Turkey is not fully thawed/
defrosted.
Never attempt to fry a frozen or
partially frozen turkey. Make sure
turkey is fully thawed/defrosted and
towel dried before lowering into oil.
Regulator control valve is not
fully opened.
Fully open regualtor control valve by
rotating it in a clockwise direction.
Over
fi
ll Protection Device (OPD)
on LP tank has been activated/
tripped.
To reset the Over
fi
ll Protection Device,
turn the regulator control valve and
the LP tank valve OFF. Disconnect the
regulator from the LP tank and wait
at least one minute. Reconnect the
regulator to the LP tank and fully open
LP tank valve.