DELAYED EGRESS INITIATION:
390/390-2 DEL
MAGNETIC LOCKING SYSTEM
9
Form 39990 Rev. E
09/23/2005
AUTOMATIC RELOCK ON POWER-UP/FIRE ALARM RESET
DOOR FORCED/PROPPED ALARM (SEC REQUIRED)
UNLOCK ALERT (HORN SOUNDS WHENEVER DOOR IS UNLOCKED
ANTI-TAILGATE (SEC REQUIRED)
1
2 3 4 5 6 7 8
TERMINAL LAYOUT TB1:
POWER INPUT
12/24 VOLTS
AC OR DC
(AUTOMATIC
SELECTION)
DO NOT
APPLY
120 VAC
FIRE ALARM
INPUT
APPLY A
NORMALLY
CLOSED DRY
CONTACT OR
A JUMPER IF
NOT
CONNECTED
TO FIRE
ALARM
AUXILIARY
INPUT
(SEE
DIPSWITCH
SETTINGS
BELOW)
C NO
ALARM
OUTPUT
(STANDARD)
CONTACTS
CHANGE
STATE
DURING
ALARM
CONDITION
RELEASE
INPUT
DRY
CONTACT
CLOSURE
WILL
RELEASE
LOCK FOR
THE TIME
DELAY
PERIOD (SEE
PAGE 14)
RESET
INPUT
DRY CONTACT
CLOSURE
RESETS LOCK
IN ALARM
CONDITION.
NO C NC
DSM OUTPUT
(OPTIONAL)
CONTACTS CHANGE
STATE WHEN DOOR IS
CLOSED.
C NC NO
MBS OUTPUT
(OPTIONAL)
CONTACTS CHANGE
STATE WHEN MAGNET
IS PROPERLY BONDED
TO ITS ARMATURE.
POOR BOND CAN BE
CAUSED BY LOW
VOLTAGE, MISALIGN-
MENT OR DAMAGED
MATING SURFACES.
DELAYED EGRESS TIME:
15 SECONDS 30 SECONDS
ON
DELAYED EGRESS
TRIGGERED BY
PLUNGER SWITCH
ONLY.
DELAYED EGRESS
TRIGGERED BY
PLUNGER SWITCH
OR AUX. INPUT.
DELAYED EGRESS
TRIGGERED BY
PLUNGER SWITCH
AND AUX. INPUT.
DELAYED EGRESS
DISABLED.
DISABLED
ENABLED
DISABLED
ENABLED
DOOR WILL RELOCK AS SOON AS IT CLOSES - EVEN
IF THE RELOCK TIME DELAY HAS NOT ENDED.
POWER MUST STILL BE APPLIED TO TERMINALS 1&2.
CODE/iButton, PIR, OR LEGAL RELEASE INPUT MUST
BE TRIGGERED. AVAILABLE ON ALL MODELS.
DISABLED
ENABLED
WHEN ENABLED, LOCK WILL ENERGIZE UPON
REGAINING POWER OR AFTER A FIRE ALARM
CONDITION CLEARS.
NUISANCE ALERT
DISABLED
ENABLED
HORN SOUNDS DURING NUISANCE ALERT.
TERMINAL LAYOUT TB9:
IF YOUR SYSTEM USES A KEYPAD
/
READER
WITH A
100CAB
ADAPTER CABLE OR A
TR80
OR
TR81,
CONNECT THE WIRES
AS SHOWN
.
KEYPADS WILL NEED TO BE
INITIALIZED
.
SEE KEYPAD OR I
B
UTTON
PROGRAMMING FOR FURTHER
INFORMATION
.
DIPSWITCH SW-4
SETTINGS:
Set the dipswitches as required for
your system.
SW-4
WHITE
BLACK
RED
SW4-4:
SW4-5:
DISABLED
ENABLED
FORCED:
ALARM SOUNDS UNTIL RESET BY
CODE/iButton OR RESET INPUT ON TERM. 17&18.
PROPPED:
AFTER PRE-SET TIME (SEE PG. 14 ) ALARM
SOUNDS UNTIL DOOR CLOSES AGAIN.
SW4-6:
SW4-7:
SW4-8:
SW4-3:
SW4-2:
SW4-1: