Installation & Operation Manual
1
Determine water heater location
8
13"
TOP
18" (457 MM)
FRONT
14" (356 MM)
REAR
12"
(305 MM)
LEFT
0"
RIGHT
OPEN
FRONT
1/4" (6 MM) MINIMUM CLEARANCE
AROUND HOT WATER PIPES
1" (25 MM) MINIMUM CLEARANCE
AROUND VENT PIPE
DIR #2000589270 00
Figure 1-2
Alcove Installation - Minimum Required Clearances
13"
TOP
12"
(305 MM)
LEFT
14" (356 MM)
REAR
6" (152 MM)
FRONT
6"
0"
RIGHT
VENTILATING*
AIR OPENING
VENTILATING*
AIR OPENING
CLOSED DOOR
1/4" (6MM) MINIMUM CLEARANCE
AROUND HOT WATER PIPES
1" (25 MM) MINIMUM CLEARANCE
AROUND VENT PIPE
DIR #2000589268 00
Figure 1-1
Closet Installation - Minimum Required Clearances
⚠
WARNING
⚠
WARNING
For closet installations, CPVC,
polypropylene or stainless steel
vent material MUST BE used in
a closet structure due to elevated
temperatures. Failure to follow
this warning could result in fire,
personal injury, or death.
For alcove installations, CPVC,
polypropylene or stainless steel
vent material MUST BE used in
an alcove structure due to elevated
temperatures. Failure to follow
this warning could result in fire,
personal injury, or death.