33
4.
START THE GENERATING SET
Warning:
Do not hook up tools or other apparatus to the generating set before starting.
Turn the starting key to “ON” position. Now you turn the starting key to “START”.
Wenn the motor is running, you can turn the starting key to “ON” position.
Caution:
•
Running the starting motor for a long time will cost the battery power greatly
even burn out the motor
•
Always leave the starting key at ON position while the engine is running
BATTERY
Check the battery electrolyte level every month. Refill the distelled water until
the upper limits if the electrolyte dropped to the lower limits.
Caution:
If the electrolyte level is too low, the engine may fail to start because there is not
sufficient power. On the other side, if the electrolyte level is too high, the fluid will
corrode the surrounding parts.Do keep the electrolyte level between the upper
and lower limits.
5. OPERATE THE GENERATING SET
5.1 Operate the generating set
1. Warm up the engine without load three minutes.
2. Concerning the generating set with Low Oil Warning System, check that the
Oil Alarm Lamp is not lit.
Caution:
•
For the generating set with Low Oil Warning System, the oil alarm lamp will
activated by low oil pressure or engine oil shortage, simultaneously, the
engine will stop. The engine will stop immediately if restarted without refilling
engine oil. Check the oil level and refill.
•
Do not loosen or readjust either the engine speed limiting bolt or fuel injection
limiting bolt, otherwise, the performance will be affected.
5.2 Checks during the running
1. Whether there is abnormal sound or vibration;
2. Whether the engine misfires or runs rough;
3. Check the color of the exhaust. (Is it black or too white?)
If you notice any of the above-mentioned phenomenon happened, stop the
engine and find out the fault cause or contact with our agents.