LMI RFP Series Instruction Manual Download Page 3

3

9.  Apply Teflon tape or pipe thread sealant on tapered
pipe thread ends of the meter couplings on 3/4", 1" or
1 1/2" models.

10.  Air trapped in the Flowmeter should be removed
prior to operation. To accomplish this, loosen the meter
couplings slightly (for models so equipped) and rotate
the Flowmeter slowly so that register is upside down.
Open upstream (inlet) valve slowly letting water through
the meter. Rotate Flowmeter slowly again until the
register is upright and tighten meter couplings. The
Flowmeter is now ready for cable connection to the
Remote Programmable Divider.

B. REMOTE PROGRAMMABLE DIVIDER

1.  The Remote Programmable Divider may be located up
to 100 feet from the Flowmeter. The unit has molded-in 4
mounting holes that will accept 1/4" diameter screws for
wall mounting.

2.  Once the Remote Programmable Divider and the
Flowmeter have been installed, connect the cable from
the Flowmeter to the programmable divider by plugging
the connector on the cable into the receptacle on the
programmable divider.

CONNECTOR INSTALLATION

C. METERING PUMP

1. Installation of your LMI metering pump should be in
accordance with instructions included with the pump.

2. Plug the connector from the programmable divider into
the receptacle located on the bottom of the pump’s
control panel.

3. To prime the pump, switch to the INTERNAL mode
and follow the PRIMING PROCEDURES on the LIQUID
END ASSEMBLY INSTRUCTION SHEET. Once the
pump is primed, switch to the EXTERNAL mode for
meter pacing.

4. Set divider number on the programmable divider
according to instruction in the next section.

5. Check treated water for desired dosage.

6. Adjust stroke length knob until desired dosage is
obtained.

IMPORTANT:

PUMP MUST BE IN THE EXTERNAL MODE FOR

METER PACING.

REMOVING PANEL

BEFORE

POWER CORD

0

50

40

30

20

10

60

70

80

90

100

DISCONNECT

E

P

E

S

D

EMPTY

INTERNAL

EXTERNAL

T

MILTON ROY

NSF

N

P

R

E

S

S

U

R

O

R

O

C

L

E

ACTON, MA 01720 U.S.A.

MILTON ROY

TURN WHILE

UNIT IS
RUNNING

STROKE

E

X

T

E

R

N

A

I

N

P

U

T

OFF

5

10

20

30

40 50 60 70

80

90

100

L

TO ADJUST

LIQUID METRONICS DIVISION, ACTON, MA 01720 U.S.A.

PROGRAMMABLE

DIVIDER

PD-4

POWER SOURCE
WITH GROUND

SOLUTION INJECTION 

PROGRAMMABLE

DIVIDER

METER COUPLING

FLOWMETER

LMI METER PACED
PUMP

WHITE TO PIN 1 OF CONNECTOR

BROWN TO PIN 2 OF CONNECTOR

GREEN TO PIN 3 OF CONNECTOR

Summary of Contents for RFP Series

Page 1: ...g data Model No Serial No Installation Date Installation Location When ordering replacement parts for your LMI Controller or accessory please include the complete Model Number and Serial Number of you...

Page 2: ...rupted run of straight pipe with a length at least 10 times the nominal diameter of the Flowmeter both upstream and downstream is need to ensure accurate readings 4 If the pipe line downstream from th...

Page 3: ...1 Installation of your LMI metering pump should be in accordance with instructions included with the pump 2 Plug the connector from the programmable divider into the receptacle located on the bottom...

Page 4: ...nit The speed of the pump is controlled automatically based on the flow of the water through the flowmeter On the LMI A7 pump external mode is accomplished by turning the speed knob fully counter cloc...

Page 5: ...tting on pump and strokes per minute in step 5 C Example C Square Root of Percent output desired from pump C 3 DETERMINE THE STROKE SETTING Model Pipe Flow GPM Flow LPM Primary Pulses Primary Pulse Si...

Page 6: ...emove the clear window on the programmable divider by removing the two black thumb screws B Set thumbwheel numbers to divider number determined above Example Using the divider number determined in the...

Page 7: ...25 L1 mm 288 378 438 in 5 35 5 79 6 34 8 6 8 440 9 370 12 560 H mm 136 147 161 218 214 240 319 in 1 61 1 75 1 81 3 27 3 87 4 62 6 h mm 41 44 46 83 99 117 152 in 1 1 25 2 6 5 7 5 9 18 D mm 165 190 228...

Page 8: ...8 RFP 07 RFP 10 RFP 15 RFP 20...

Page 9: ...9 RFP 30 RFP 40 RFP 60...

Page 10: ...RE 32 to 120 O F 0 to 50O C MAXIMUM OPERATING PRESSURE 200 psi 13 8 Bar RFP 30 RFP 40 RFP 60 TYPE Magnetic Drive Turbine Meter BODY Bronze REGISTER Straight reading US Gallons center sweep hand protec...

Page 11: ...s All Models All Models All Models 31271 Remote Programmable Divider Asm 1 1 1 1 1 1 1 31135 Housing 1 26740 Gasket Asm 1 31277 Connector Asm 1 31278 Cable Asm 1 30990 Divider Asm 1 26314 Switch 1 264...

Page 12: ...12 1996 LMI Milton Roy All Rights Reserved Printed in USA Specifications subject to change without notice...

Reviews: