INSTALLATION

TYPICAL INSTALLATION

I. UNPACKING

A.  Remote Flowmeter (RFP) units are packaged in two
separate cartons. One carton contains the Flowmeter and
10 feet of cable for direct hookup to the Remote Program-
mable Divider. The other carton contains the Remote
Programmable Divider complete with 10 feet of cable for
direct connection to an LMI metering pump.

B.  Remote Flowmeter units in 3/4", 1", and 1 1/2" sizes
have a pair of union couplings and gaskets included. The
2", 3", 4" and 6" sizes have flange connections.

C.  Because of test water residue, the Remote Flowmeter
should be stored in a frost-proof area. If this is not
possible, the Remote Flowmeter must be thawed prior to
installation.

II. LOCATION

A. Flowmeter

1.  Remote Flowmeters should be installed in a frost-
proof, easily accessible area.

2.  To prevent accumulation of air and a resultant error in
measurement, the Flowmeter should be installed on the
lowest horizontal point of the pipeline.

3.  An uninterrupted run of straight pipe with a length at

least  10 times the nominal diameter of the Flowmeter
both upstream and downstream is need to ensure accurate
readings.

4.  If the pipe line downstream from the Flowmeter is
open discharge, the  pipe must be raised so open dis-
charge elevation is higher than the top of the Flowmeter
(see "Typical Installation" drawing below).

5.  Thoroughly rinse the pipeline by opening the upstream
shut-off valve before installing the Flowmeter.

6.  The Remote Programmable Divider may be located as
far as 100 feet from the Flowmeter location. Extension
cables are available. Please consult the factory if the
Remote Programmable Divider will be installed more
than 100 feet from the Flowmeter.

7.  The flowmeter must be installed horizontally  and
level, with the glass register positioned up (12:00 posi-
tion--see "Typical Installation" drawing).

8.  For ease of installation, install a shut-off valve, with an
orifice diameter at least as large as the nominal size of the
Flowmeter. Installation of a bypass is also recommended
for easy removal or servicing of the Flowmeter without
interrupting the water flow (see "Typical Installation"
drawing).

Summary of Contents for RFP Series

Page 1: ...g data Model No Serial No Installation Date Installation Location When ordering replacement parts for your LMI Controller or accessory please include the complete Model Number and Serial Number of you...

Page 2: ...rupted run of straight pipe with a length at least 10 times the nominal diameter of the Flowmeter both upstream and downstream is need to ensure accurate readings 4 If the pipe line downstream from th...

Page 3: ...1 Installation of your LMI metering pump should be in accordance with instructions included with the pump 2 Plug the connector from the programmable divider into the receptacle located on the bottom...

Page 4: ...nit The speed of the pump is controlled automatically based on the flow of the water through the flowmeter On the LMI A7 pump external mode is accomplished by turning the speed knob fully counter cloc...

Page 5: ...tting on pump and strokes per minute in step 5 C Example C Square Root of Percent output desired from pump C 3 DETERMINE THE STROKE SETTING Model Pipe Flow GPM Flow LPM Primary Pulses Primary Pulse Si...

Page 6: ...emove the clear window on the programmable divider by removing the two black thumb screws B Set thumbwheel numbers to divider number determined above Example Using the divider number determined in the...

Page 7: ...25 L1 mm 288 378 438 in 5 35 5 79 6 34 8 6 8 440 9 370 12 560 H mm 136 147 161 218 214 240 319 in 1 61 1 75 1 81 3 27 3 87 4 62 6 h mm 41 44 46 83 99 117 152 in 1 1 25 2 6 5 7 5 9 18 D mm 165 190 228...

Page 8: ...8 RFP 07 RFP 10 RFP 15 RFP 20...

Page 9: ...9 RFP 30 RFP 40 RFP 60...

Page 10: ...RE 32 to 120 O F 0 to 50O C MAXIMUM OPERATING PRESSURE 200 psi 13 8 Bar RFP 30 RFP 40 RFP 60 TYPE Magnetic Drive Turbine Meter BODY Bronze REGISTER Straight reading US Gallons center sweep hand protec...

Page 11: ...s All Models All Models All Models 31271 Remote Programmable Divider Asm 1 1 1 1 1 1 1 31135 Housing 1 26740 Gasket Asm 1 31277 Connector Asm 1 31278 Cable Asm 1 30990 Divider Asm 1 26314 Switch 1 264...

Page 12: ...12 1996 LMI Milton Roy All Rights Reserved Printed in USA Specifications subject to change without notice...

Reviews: