12.0 EPU Resistance Chart
*
Let pump cool down completely before checking resistance. EPU checked
within 10 hours of operation can increase coil resistance reading as much
as 20%.
NOTES:
1. Pumps with serial numbers
LOWER
than:
960113429
2. Pumps with serial numbers
HIGHER
than:
960113429
Pump Series
Voltage
Coil Resistance
(Ohms)
@ 20
o
C (68
o
F)*
PW4, PW5, PW6
P04, P05, P06
115 VAC
76 - 87
P14, P15 P16
230 VAC
307 - 353
P74, P75, P76
(see Note 1)
P02, P03
115 VAC
152 - 176
P12, P13
230 VAC
583 - 671
(see Note 2)
AA14, AA74, AA94
115 VAC
76- 87
AA15, AA75, AA95
230 VAC
291- 335
AA16, AA76, AA96
AA17, AA77, AA97
P02, P03
P12, P13
J54D, J55D, J56D
12 VDC
1.1 - 1.3
E70, E71, E72, E73, E74
115 VAC
22.8 - 26.2
230 VAC
91 - 105
B11, B12, B13, B14
115 VAC
43 - 49
B71, B72, B73, B74,
230 VAC
167 - 193
B91, B92, B93, B84
C10, C11, C12, C13, C14
115 VAC
22.8 - 26.2
C70, C71, C72, C73, C74
230 VAC
91 - 105
C90, C91, C92, C93, C94
C76, C77, C78
115 VAC
14.4 - 16.6
230 VAC
57.7 - 66.3