LMF Clima HRH 05 Installation, Operation And Maintenance Manual Download Page 19

 

MIUM0018_REV05_ HRH&HRS

_20170206-MIUM-

 

5

 

 

W

IRING 

D

IAGRAMS

 

 

Each unit is provided with internal wiring
following table : 
 

HRH/HRS Model

 

05 

10-15-20 

30-40 

 
In the back of electrical box panel it is a
the installer; wiring diagrams of options a
 
 
 

6

 

 

E

LECTRONIC 

C

ONTROL

 

 

Follow instructions of Control Manual su
 
 
 

7

 

 

S

CHEDULED AND 

N

OT

-

S

 

 

 

 

It is the responsibility of the Use

 

Only personnel previously train

 

Should the unit require disasse

 
Maintenance  keeps  unit  efficiency,  red
understand  the  efficiency  of  the  unit  a
European legislation. Provide a machine
to cadence adequately the various interv
Please  take note  of:  date,  type  of actio
registered in the alarm history, etc. ... 

 
7.1 Scheduled monthly check 

 

7.1.1 Air filters 

 
Air filters are placed close to unit air inle
 

 

for horizontal unit, by lower hinged
these doors maintenance is both fo

 

for vertical unit, by front hinged doo
doors maintenance is both for filter

 
Other special access to filter is also poss
 

 

for horizontal unit, by removing an 

 

for vertical unit, by removing an up

  
 
 

BEFORE SERVICIN

 

-ENG

 

ng diagram, characterized by specific code. To match co

Wiring diagram c

AMF0008070
AMF0008071
AMF0008072

 also printed the basic unit external wiring diagram, conn
s are shown on specific sections of Control Manual (see 

 

supplied with the unit (document code 

MC00008

, valid fo

SCHEDULED 

M

AINTENANCE

 

ser to carry out all types of maintenance operations. 

ined and qualified may carry out maintenance operation

sembly, hand and body protections are required. 

 

educe  the  speed  of  deterioration  over  time  and  collec

and  prevent  failures.  We  suggest  to  prepare  a  bookle

ne book that allows you to track of the actions taken on 

rventions and will facilitate a possible troubleshooting. 

tion,  description of  action, measurements performed,  an

 

lets and are usually accessible : 

ed doors provided with recessed handles and kept clos

 for filter and fan; 

fig. 12a

oors provided with recessed handles and kept closed by

er and fan; 

fig. 12b

ssible : 

n end side panel provided with recessed handle (

fig. 13a

pper end panel provided with recessed handle (

fig. 13b

ING THE UNIT, SWITCH OFF THE MAIN POWER SU

19

ENG

 

 code and unit model see the 

 code 



nnection to be carried out by 

e next Chap. 6). 

 for all HRH/HRS models). 

ns. 

lect  information  and  data  to 

klet  of  installation  according 

n the unit, so it will be easier 

anomalies  identified,  alarms 

sed by blocking devices (by 

 by blocking devics (by these 

3a

b

SUPPLY. 

Summary of Contents for HRH 05

Page 1: ...manual m ENG T TI IO ON N O OP PE ER RA AT TI IO O N NC CE E M MA AN NU UA AL L NTILATION UNIT WITH FICIENCY HEAT RECOV SERIES HRH HRS possono essere soggetti ad aggiornamento L azienda si riserva il...

Page 2: ...a CE indelible marking complete with the supply of an User manual Meledo di Sarego VI 23 12 2015 ENG MF product It is the result of many years of experienc ghly advanced technologies The CE mark guara...

Page 3: ...ORT 4 INSTALLATION CONNE 5 WIRING DIAGRAMS 6 ELECTRONIC CONTROL 7 SCHEDULED AND NOT S 8 TROUBLESHOOTING 9 MATERIAL DISPOSAL ENG ATTENTION ANGER IGH RISK OF ELECTRIC SHOCK ATTENTION AUTHORIZED PERSONNE...

Page 4: ...lete with co 5 self supporting panels This unit may be integrated with tradi equipped with the proper accessories ENG terflow heat recovery has been designed and develope s the room air renewal while...

Page 5: ...for pos Max input current A for electric Max input power W for electric ENG iring diagram and control instructions supplied with the sultation when required ensure that the unit is installed in the co...

Page 6: ...sions and weights of HRH and HRS e electrical panel like in the drawing above electrical panel 05 10 15 20 1350 1470 1850 1850 680 820 1030 1460 330 370 455 455 760 900 1110 1540 230 300 390 600 225 2...

Page 7: ...of HRH and HRS s oking at the electrical panel like in the drawing above king at the electrical panel 05 10 15 20 1350 1470 1850 1850 680 820 1030 1460 330 370 455 455 230 300 390 600 225 265 350 350...

Page 8: ...ject to flo fresh air intake and exhaust air outlet s ENG T AND STORAGE d with cardboard packaging the packaging shall remain ax one similar unit or a smaller one over the ground unit unted for techni...

Page 9: ...documents specifying the type o ent to installation place directly but stored it shall be sto sand and wind en below escribed on previous par 3 1 20 C max 60 C onsibility for damage due to a bad stor...

Page 10: ...d on the side of the unit as ENG ty of all components of the unit ith installation instructions and with its ordered options optional sections to the installation place as close as po side the unit or...

Page 11: ...r upper side do not use the bracket put screws and the rubber washers supplied together with e of installation and installation of basic un nit and its possible options shall be suitable to to horizon...

Page 12: ...ces as unit in order to carry out all serv ENG ere the condensation discharge may occur easily give requirement applies to both horizontal and vertical versio as shown on following figg 6 and 7 They a...

Page 13: ...and bars fig 8 both completely closed and with one side filter pa remounted easily If not adjust opportunely the tigh he supporting feet to the floor or to the supporting fram djacent to a vertical w...

Page 14: ...existing unit sections DX both horizontal and vertical version it is supplied cording to the instructions of next 4 5 shall be interc ng side fig 9a ments preventively unscrew the M6 screws by a 5 mm...

Page 15: ...pport feet supplied apart and to be mounted as ounting Their weight shall not load the unit ed with a series of perimetric L stirrups with built in M mounted on the unit in symmetrical positions by us...

Page 16: ...M n 10 possible air connections of which n 6 closed by in on fig 10a air inlet air outlet layout move opportunely and block do this before positioning the plenum tly sized in order to match unit exter...

Page 17: ...pling flange and supplied kit compos ews B as shown on fig 10b he perimeter of the flange place the damper in correspo haft is accessible and can t interfere with unit access drilling screws nections...

Page 18: ...load the coil headers fix both annular external gaskets to avoid air leakage ery low air temperature fill the water circuit with antifree nt of plant shut off long periods at very low air temperatu f...

Page 19: ...AMF0008070 AMF0008071 AMF0008072 also printed the basic unit external wiring diagram conn s are shown on specific sections of Control Manual see supplied with the unit document code MC00008 valid fo S...

Page 20: ...d screwdriver after remounting filte frame then block it fig 12c ENG filter elements is prevented by a filter locking plate to b ter elements turn the locking plate in the opposite direct Fig 12a Fig...

Page 21: ...filter pre ENG using an AW20 head tool to unscrew For horizon n remove it by side 2 in order to not interfere with the directly move the panel upwards ed with compact filters F7 class efficiency on fr...

Page 22: ...sizes gradually loosen t removed for HRH HRS 30 and drive the For replacing the new fan operate accor B ENG t all electrical connections are well tightened ter connections is needed but the visual ch...

Page 23: ...actuator from its plastic lo 3 lift the actuator up to make it free from Fig 16a D ENG t of by pass actuator al of middle panel bewteen the two end panels for specia intermediate support see previous...

Page 24: ...on acc fixed on each upper side by M6 screws ENG ording to the opposite sequence taking care of keepin use the little magnet to make actuator rotation neutra pass duct is in closed position ow 30 and...

Page 25: ...tection on Fan speed signal missing Swi Res con Che Che sett Air filter dirty Air duct clogged Fan signal too low Rep Che Adju Temperature setpoint not right Heat transfer fluid rate not right Heat tr...

Reviews: