front
right
back
underside left-back
back
Notice: do not raise the
drain hose.
The connecting pipe can be led
from back, right, underside,
or left-back side.
Cover connecting pipe with
adiabatic material.
Sponge plastic adiabatic
material with the
thickness of 8mm.
While installing the pipeline on the
thin armor plate or on the wall of
metal mesh, you should use the
wooden board to clamp between
the wall and the pipeline, or wrap
up the pipeline with 7-8 layers of
insulating plastic tape.
left
INSTALLATION SKETCH
2
Confirm the installation position by the mark of the indoor mounting plate.
or
or
or
above 155mm
above 250mm
Above 20mm
above 105mm
100mm以上
above 300mm
above 500mm
above 300mm
above 500mm
above 500mm
Single Split Model
OR
A
B
TO INDOOR UNIT
above 500mm
above 300mm
above 300mm
Above 500mm
above 500mm
T
O INDOOR UNIT
Dual Split Model
B
TO INDOOR UNIT
A
above 300mm
above 500mm
above 300mm
above 500mm
above 500mm
A
B
A
B
A
B
TO INDOOR UNIT
above 500mm
above 300mm
above 300mm
above 500mm
Above 500mm
T
O INDOOR UNIT
Dual inverter Model
A
B
T
O INDOOR UNIT
Attention:
The allowable length of the connecting
pipe is 10m.
The allowable distance between indoor
unit and outdoor unit is 5m.