background image

2

33.C.159.1409

Quick Guides | ICS.2

Back to start

Check the antenna connections.

Connect the receiver unit to the 
power grid.

Connect the actuators to the lower row of connectors in the receiver unit. The 
connectors for the actuators are marked 

.

Up to three actuators can be connected to one connector.

If wired thermostats are to be used in the system, these should be connected 
to the upper row in the receiver unit. The connectors for the thermostats are 
marked 

.

A maximum of one thermostat per thermostat connector. 

Installation of ICS.2 Systems

Connecting actuators and wired thermostats

1.1

Termostater / Thermostats

Ställdon / Actutators

1

M

U

L

A

1

1

2

3

7

4

5

6

8

3

2

8

7

6

5

4

230VAC

FUSE

BOILER

PUMP

2

M

1

M

BUS

SETBACK

Pwr

3

M

4

M

5

M

6

M

7

M

8

M

NO

T

NC

SET

V

V

1

1.2

1.3

Summary of Contents for ICS.2

Page 1: ...LK ICS 2 Quick Guides Installation Reset Installation Svenska Reset Svenska Installation English Reset English ...

Page 2: ...o one connector If wired thermostats are to be used in the system these should be connected to the upper row in the receiver unit The connectors for the thermostats are marked A maximum of one thermostat per thermostat connector Installation of ICS 2 Systems Connecting actuators and wired thermostats 1 1 Termostater Thermostats Ställdon Actutators 1 M U L A 1 1 2 3 7 4 5 6 8 3 2 8 7 6 5 4 230VAC F...

Page 3: ...ntil the lights of the receiver unit lights up to a solid green light This shows that the unit is set as Master In a system containing several receiver units one of these is to be assigned as being the Master unit Del 2 Setup of the Master unit Note This part of the setup procedure should be performed in all systems 2 1 ...

Page 4: ...uick Guides ICS 2 Back to start Confirm the setup of the Master unit by pressing the L button once This switches all the lights of the unit off The unit is preferably marked as Master in the lid of the receiver unit 2 2 ...

Page 5: ...S 2 Back to start Put the Master unit in learning mode by holdning the L button until the light turns a solid green 3 1 Del 3 Setup of Slave units Note This part of the setup is only needed in systems with more than one receiver unit ...

Page 6: ... to be set as Slaves until the L light turns orange The light for the channel which is assigned to the receiver unit turns on to a green light Slave units are assigned a number ranging from 2 to 8 The receiver unit is preferably marked as a Slave and its assigned number in the lid of the receiver unit 3 2 ...

Page 7: ...59 1409 Quick Guides ICS 2 Back to start Push the L button on the Slave unit to confirm the setup This turns all the lights of the unit off Repeat these steps for each additional receiver unit in the system 3 3 ...

Page 8: ... 159 1409 Quick Guides ICS 2 Back to start When all Slave units are setup the procedure is finalized by pressing the L button on the Master unit once All the lights on the Master unit will be switched off 3 4 ...

Page 9: ... compartment marked in the red circle The room thermostat display will show RUR Wired room thermostat Check that the room thermostat is connected to the receiver The room thermostat display will show RUW Note The installation of the room thermostats is the same whether it is a wireless or wired connection to the receiver Del 4 Setup of room thermostats 4 1 ...

Page 10: ...10 33 C 159 1409 Quick Guides ICS 2 Back to start Put the receiver unit that is to be controlled by the room thermostat in learning mode by pressing the L button until the L light turns green 4 2 ...

Page 11: ...11 33 C 159 1409 Quick Guides ICS 2 Back to start On the thermostat hold SET until the display shows MATE 4 3 ...

Page 12: ...ht and a solid green for the channel lights Choose the channel or channels by pressing the corresponding channel buttons 1 8 To show that a channel has been chosen the light for that channel starts to blink Press the channel button again to undo a choice of channel Already occupied channels are shown by an orange light 4 4 ...

Page 13: ...eceiver unit this might take a while If this process takes an unreasonable long time the synchronizing can be restarted by pressing SET once more When the synchronizing process is done the display will show the standard mode showing temperature and other miscellaneous information This confirms that the setup is completed for this thermostat Repeat the steps for each thermostat that is to be connec...

Page 14: ...e setup the process is completed by pressing the L button on the receiver unit once Repeat Part 4 of this Quick Guide for every receiver unit in the system The installation of ICS 2 is completed when all the thermostats are setup together with their respective receiver unit 4 6 ...

Page 15: ...If a termostat for some reason no longer is communicating with its receiver unit the termostat needs to be reset and setup once more To begin resetting a termostat hold both the left and right arrow buttons until the display shows DEFA Resetting of ICS 2 Systems Resetting Thermostats 1 1 1 2 ...

Page 16: ...actory default mode Wireless thermostats will display RUR Wired thermostats will display RUW If the termostat can t communicate with its receiver unit during the reset the display will show WAIT during a longer period If this happens push both the left and right arrow button once more to confirm the reset 1 3 1 4 ...

Page 17: ... all connections to all the termostats paired to this receiver unit as well as all other receiver units These connections needs to be setup again for the system to function as intended Remove one of the batteries for about 15 seconds to make sure the reset is completely carried out Mind the polarity of the batteries and make sure that it remains the same when the battery is put back in 1 5 2 1 Res...

Page 18: ... If you reset the Master receiver unit in a system all the Slave receivers needs to be reset as well Disconnect the power to the receiver unit for about 30 seconds to make sure the reset is fully completed 2 2 2 3 Master Receiver Unit Slave Receiver Unit s ...

Page 19: ...s till varje ställdonsutgång Om systemet innehåller trådförbundna termostater ska dessa anslutas i den övre plintraden märkta Max en rumstermostat per termostatingång Installation av ICS 2 System Inkoppling av Ställdon och trådförbundna termostater 1 1 Termostater Thermostats Ställdon Actutators 1 M U L A 1 1 2 3 7 4 5 6 8 3 2 8 7 6 5 4 230VAC FUSE PUMP 2 M 1 M BUS SETBACK Pwr 3 M 4 M 5 M 6 M 7 M ...

Page 20: ...apparna tills lamporna för L och samtliga kanaler tänds till ett grönt sken Detta visar att denna enhet är inställd som Master I system med flera mottagarenheter utses en av dessa till Master enhet 2 1 Del 2 Inlärning av Masterenhet Notera Denna del ska utföras i alla installationer oavsett antal mottagarenheter ...

Page 21: ... Quick Guides ICS 2 Tillbaka till start Bekräfta inställningen av Master enheten genom att trycka en gång på L knappen Detta släcker alla lampor på enheten Märk gärna enheten som Master i locket för mottagarenheten 2 2 ...

Page 22: ...l start Ställ Master enheten i inlärningsläge genom att hålla inne L knappen tills lampan för L tänds till ett ett fast grönt sken 3 1 Del 3 Inlärning av Slave enheter Notera Denna del behöver endast utföras i installationer med flera mottagarenheter ...

Page 23: ... på en mottagarenhet som ska vara Slave enhet tills dess L lampa lyser orange Lampan för den kanal som Slave enheten blivit tilldelad lyser grönt Slaves blir tilldelade nummer från 2 till 8 Märk gärna enheten som Slave och dess tilldelade kanal i locket för mottagarenheten 3 2 ...

Page 24: ...1409 Quick Guides ICS 2 Tillbaka till start Tryck en gång på L knappen på Slave enheten för att bekräfta inlärningen Detta släcker samtliga lampor på enheten Upprepa stegen för övriga mottagarenheter i systemet 3 3 ...

Page 25: ...59 1409 Quick Guides ICS 2 Tillbaka till start När samtliga Slave enheter är inlärda avslutas inlärningen genom att trycka en gång på Master enhetens L knapp Alla lampor på Master enheten ska nu vara släckta 3 4 ...

Page 26: ...mostatens display ska visa RUR Om du har trådbundna rumstermostater Kontrollera att termostaten är inkopplad i mottagarenheten på rätt plats se del 1 1 av Quick Guiden Termostatens display ska visa RUW Notera I övrigt är installationen av termostaterna lika oavsett om det är en trådlös eller trådförbunden förbindelse med mottagarenheten Del 4 Inlärning av Rumstermostater 4 1 ...

Page 27: ...59 1409 Quick Guides ICS 2 Tillbaka till start Ställ den mottagarenhet som ska styras av rumstermostaten i inlärningsläge genom att hålla inne L knappen tills lampan för L tänds till ett ett fast grönt sken 4 2 ...

Page 28: ...28 33 C 159 1409 Quick Guides ICS 2 Tillbaka till start På termostaten håll inne SET tills displayen visar MATE 4 3 ...

Page 29: ... och ett fast grönt ljus för kanal lamporna Välj in den de kanaler som termostaten ska styra genom att trycka på motsvarande kanal knapp 1 8 För att visa att en kanal har blivit vald blinkar dess lampa Tryck igen på en kanal knapp för att ångra ett val Redan upptagna kanaler visas med ett orange sken för dess kanal lampor 4 4 ...

Page 30: ...ottagarenheten detta kan ta en stund Om termostaten tar oväntat lång tid på sig att synkronisera kan denna synkroniseringsprocess startas om genom att trycka på SET knappen en gång När synkroniseringen är färdig visar termostaten standardläget med temperatur och övrig information Detta bekräftar att inställningen är utförd Upprepa stegen för varje rumstermostat som ska anslutas till denna mottagar...

Page 31: ...tagarenhetens L knapp Upprepa Del 4 av guiden för varje mottagarenhet i systemet Installationen av ICS 2 är slutförd när samtliga termostater är inlärda mot sina respektive mottagarenheter Om du skulle vilja återställa hela eller delar av ICS 2 systemet se Quick Guide Reset ICS 2 Denna innehåller också grundläggande felhantering vid problem 4 6 ...

Page 32: ...stat av någon anledning inte längre kan kommunicera med sin tilldelade mottagarenhet behöver denna termostat återställas och läras in på nytt För att påbörja en återställning av en rumstermostat hålls knapparna för både pil höger och pil vänster ner samtidigt tills displayen visar DEFA Reset av ICS 2 Systems Reset av Termostater 1 1 1 2 ...

Page 33: ...tt icke inlärda ursprungsläge Trådlösa termostater visar RUR i displayen Trådförbundna termostater visar RUW i displayen Om termostaten inte kan kommunicera med sin mottagarenhet visar displayen WAIT under en längre period Tryck då på både pil höger och pil vänster samtidigt för att återställa termostaten 1 3 1 4 ...

Page 34: ...r lyser rött Detta raderar alla anslutningar till rumstermostater samt alla kommunikationer mellan olika mottagarenheter i systemet Detta behöver installeras på nytt för att systemet ska fungera som tänkt Plocka ut ett batteri under en period på ca 15 sekunder för att säkerhetsställa att återställningen är helt färdig Notera polariteten och tillse att den blir samma när batteriet åter sätts in i t...

Page 35: ...ter enheten återställs så måste också alla Slave enheter i ett system återställas Koppla ur strömförsörjningen till mottagarenheten under ungefär 30 sekunders tid för att säkerhetsställa att enheten blir helt återställd 2 2 2 3 Master Mottagarenhet Slave Mottagarenhet er ...