background image

2 (9)

Installation

1.  Install the water safety system on the in-

coming water pipe directly after the water 

meter isolation valve and any check valve.

2.  Tighten the couplings without damaging 

the plastic casing on the water safety sys-

tem.

The water safety system and the incoming water pipe.

TIP! The water safety system is equipped with a 

counterhold on the underside. Use an adjustable 

wrench on the counterhold. It is also possible to 

use a screwdriver in the slot to create a counter-

hold.

The counterhold on the underside of the water safety 

system.

The water safety system installed in the cabinet.

Preparing for installation

The water safety system must be installed by a 

plumber according to the Safe Water Installation 

industry regulations.

TIP! The water safety system is equipped with 

a G20 EuroCone external thread which is to be 

installed with an LK PressPex press connection 

coupling or LK Pushfit AX connection coupling. 

When using a flat gasket, LK Plain Adapter is 

supplied

(RKS-187 06 78) with the product. 

NOTE!

Safety systems such as residential sprinklers 

and emergency cooling of solid fuel boilers or 

similar must be connected before the water 

safety system. If they are installed after-

wards, they risk being left without a water 

supply.

NOTE!

Install the water safety system after supplying 

safety systems that require water.

NOTE!

Water filters that are backwashed should 

also be connected before [word missing] to 

avoid interfering with its function. The system 

prevents water damage that may occur after 

the position of the water safety system.

Correct installation of the water safety system.  

The arrows show the direction of water flow.

EN.40.C.12.2021-12-06

Installation instructions | LK CubicSecure

Summary of Contents for CubicSecure

Page 1: ...em description LK CubicSecure is a small unit that is easy to install in confined spaces The unit is easily in stalled on incoming water pipes for a house or apartment The water safety system is equipped with a switch for manual shut off in the event of power failure or emergency NOTE Two water safety systems can be paired in order to avoid scalding in apartments Pairing provides a synchronised au...

Page 2: ...er safety system is equipped with a G20 EuroCone external thread which is to be installed with an LK PressPex press connection coupling or LK Pushfit AX connection coupling When using a flat gasket LK Plain Adapter is supplied RKS 187 06 78 with the product NOTE Safety systems such as residential sprinklers and emergency cooling of solid fuel boilers or similar must be connected before the water s...

Page 3: ...K app 1 Download and install the LK app from the App Store or Google Play Store 2 Launch the LK app and log in The login page in the LK app Startup 1 Connect power to the unit using the micro USB power adapter included The water safety system connected to the power source 2 Check that the STATUS LED is WHITE White light indicates that the unit is work ing normally If no LEDs are lit check that the...

Page 4: ...e_XXXX 8 Select the name of the wireless network and enter the password 9 Confirm your selection by pressing FLASH ES WHITE Selecting a wireless network 3 Check that the STATUS LED is WHITE 4 Confirm by pressing GLOWS WHITE White light the unit is working normally 5 Press the CONNECT button and check that it starts flashing WHITE 6 Confirm by pressing FLASHES WHITE White flashing light CONNECT EN ...

Page 5: ...ter pipes to protect against any leakage and avoid possible scalding Manual pairing 1 Install and start the units One for hot water and one for cold water 2 Hold down the CONNECT button for five seconds on the unit installed for cold water The CONNECT LED starts flashing YEL LOW and BLUE 3 Hold down the CONNECT button for five seconds on the unit installed for hot water The CONNECT LED starts flas...

Page 6: ... valve is open The water supply flow is on Dark Off The valve is open The water supply flow is off WHITE Flashing Indicates that there is an ongoing water flow YELLOW The position of the valve has been changed using the man ual switch Press the WATER ON OFF button to turn off the warning alarm function RED The water pressure is very low or there is no water in the pipe Check that the water system ...

Page 7: ...nfigured and con nected WHITE Flashing The unit is in hotspot mode for Wi Fi configuration RED Flashing No Internet contact with the Wi Fi network YELLOW Flashing Ongoing pairing establishment between two water safety system units one for cold water and one for hot water YELLOW BLUE Flashing Pairing completed between the hot and cold water units The connection is made from the cold water unit whic...

Page 8: ...urements via the LK app Various data such as temperature volume water pressure valve position and no leakage detected are displayed for each unit When LK CubicSe cure is in operation it performs automatic leak age tests If a fault occurs during operation the water safety system will emit an alarm and close the valve Measured values from the water safety system are shown in the LK app Use of large ...

Page 9: ...nt LK Systems is affiliated with El Kretsen for col lecting and recycling electronics and batteries Used batteries should be sorted as batteries or small batteries and deposited for battery recy cling When the system has reached the end of its life it should be sorted as electronics or other electronics and deposited with a recycling centre Guarantee LK Systems AB is responsible for faults in prod...