2 (9)
Installation
1. Install the water safety system on the in-
coming water pipe directly after the water
meter isolation valve and any check valve.
2. Tighten the couplings without damaging
the plastic casing on the water safety sys-
tem.
The water safety system and the incoming water pipe.
TIP! The water safety system is equipped with a
counterhold on the underside. Use an adjustable
wrench on the counterhold. It is also possible to
use a screwdriver in the slot to create a counter-
hold.
The counterhold on the underside of the water safety
system.
The water safety system installed in the cabinet.
Preparing for installation
The water safety system must be installed by a
plumber according to the Safe Water Installation
industry regulations.
TIP! The water safety system is equipped with
a G20 EuroCone external thread which is to be
installed with an LK PressPex press connection
coupling or LK Pushfit AX connection coupling.
When using a flat gasket, LK Plain Adapter is
supplied
(RKS-187 06 78) with the product.
NOTE!
Safety systems such as residential sprinklers
and emergency cooling of solid fuel boilers or
similar must be connected before the water
safety system. If they are installed after-
wards, they risk being left without a water
supply.
NOTE!
Install the water safety system after supplying
safety systems that require water.
NOTE!
Water filters that are backwashed should
also be connected before [word missing] to
avoid interfering with its function. The system
prevents water damage that may occur after
the position of the water safety system.
Correct installation of the water safety system.
The arrows show the direction of water flow.
EN.40.C.12.2021-12-06
Installation instructions | LK CubicSecure