- 3 -
6
SERVICE
5
M965743 Rev. 1.1 (11/18)
• Move HANDLE
(1)
into “off” position.
• Turn on water supplies and check connections for leaks.
• Operate HANDLE
(2)
up and down, left and right to flush
water lines thoroughly.
• Operate HAND SPRAY and check connections for leaks.
CHECK CONNECTIONS FOR LEAKS
CHECK CONNECTIONS
FOR LEAKS
If Faucet Drips, Proceed As Follows:
• Turn VALVE to OFF position.
• Operate HANDLE several times from OFF to ON position. Do not apply excessive force.
Reduced Flow:
• Clean out spray head screen.
• Clean out cartridge.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
• Loosen HANDLE SCREW
(1)
and remove HANDLE
(2)
.
• Unthread ESCUTCHEON CAP
(3)
. Unthread three MOUNTING SCREWS
(4)
.
• Lift CARTRIDGE
(5)
off MANIFOLD
(6)
and
remove CARTRIDGE SEALS
(7)
.
• Clean MANIFOLD
(6)
, CARTRIDGE
(5)
ports and SEALS
(7)
.
• Place SEALS
(7)
into CARTRIDGE
PORTS
(5a)
.
• Place CARTRIDGE
(5)
onto
MANIFOLD
(6)
and tighten
MOUNTING SCREWS
(5)
alternately.
• Replace ESCUTCHEON CAP
(4)
,
HANDLE
(2)
, tighten HANDLE
SCREW
(1)
.
3
4
5
5a
2
1
6
7