Livox Tele-15
Quick Start Guide
6
Unit: mm
Mounting the Livox Converter 2.0
Refer to the dimensions below to mount the Livox Converter 2.0.
74
52
22.9
37
66
4-M2 2.5
A
A
A
B
Red (Positive); Black (Negative)
Connects to the Livox Converter 2.0 power port
Connection
Connecting the Cables
Connect the included sync cable and power cable correctly based on the illustration below.
Power Cable
Sync Cable
Black (GND); Blue (PPS); White (NC),
null signal
Connects to the Livox Converter 2.0 sync port
Livox Converter 2.0 supports PPS (3.3V LVTTL level) synchronization. Refer to the Livox Tele-15
User Manual for more information.
Connecting the Livox Tele-15
The Livox Tele-15 supports two IP modes: dynamic IP address mode and static IP address mode.
All Livox Tele-15 LiDAR sensors are set to static IP address mode by default with an IP address of
192.168.1.1XX (XX stands for the last two digits of the Livox Tele-15 LiDAR sensor’s serial number).
The default subnet masks of the Livox Tele-15 LiDAR sensors are all 255.255.255.0, and their
default gateways are 192.168.1.1. Directly connect the Livox Tele-15 to the computer when using
for the first time.
1. Before connecting, set the IP address of the computer to static IP address mode. Set
the computer's IP address to 192.168.1.50, and the subnet mask of the computer to
255.255.255.0.
2. Connect the Livox Tele-15 as shown below.