Product Profile

Introduction

Livox Hub is a streamlined way to integrate and manage Livox LiDAR sensors and their data outputs. 
One Livox Hub can connect to up to nine Livox LiDAR sensor units. 
LiDAR Management: Livox Hub communicates with each connected LiDAR sensor and reads each 
sensor’s connection status, firmware version, and working states. When Livox Hub is connected, users 
can monitor all connected LiDAR sensors together through Livox Hub. If there are any abnormalities 
with Livox Hub or the Livox LiDAR sensors connected, Livox Hub sends a warning prompt. Users can 
then check the error codes using Livox Viewer or the Livox SDK. 
Each Livox LiDAR port has independent power control and short circuit protection. Users can turn the 
power supply on or off to a specific LiDAR port using Livox Viewer or the Livox SDK. 
Livox Hub can unify the point cloud data into the user’s coordinate system and integrate all LiDAR point 
cloud data into a single output. The point cloud data of Livox Hub can be displayed in Cartesian or 
Spherical coordinates, and can be changed using Livox Viewer.
Time Synchronization: Time synchronization is supported by IEEE 1588-2008 (PTPv2) and GPS, 
delivering sub-microsecond-level time synchronization of point cloud data.
Livox SDK: The Livox LiDAR Software Development Kit (SDK) is provided to help develop customizable 
applications using the point cloud data. 

• The precision of IEEE 1588-2008 (PTPv2) was tested in a lab environment. 
• Refer to the SDK Communication Protocol to check the format of the point cloud timestamps. 
• When nine Livox Mid-100 sensor units are connected to a Livox Hub, the maximum data 

bandwidth is approximately 300Mbps. 

• Operating Livox Hub in a residential environment could cause radio interference.

Overview

Livox Mid-40

1

2

4

5

6

7 8

9

3

1. Port Cover × 4

Protect the ports from damage. To view the 

ports on Livox Hub, unscrew and remove the 

port covers.

2. Status LEDs

 

Displays the working states of Livox Hub. 

Refer to Appendix 7.1 for more information. 

3. Dissipation Area

Dissipates heat. DO NOT cover this area when 

Livox Hub is in use. It is recommended to 

keep a space of 30 mm between this area and 

other objects. 

4. Livox Hub

The main section of Livox Hub, which can be 

used with or without the port covers. 

Summary of Contents for Hub

Page 1: ...Livox Hub v1 0 2019 02 User Manual ...

Page 2: ...vox Viewer Visit the link below to download Livox Viewer https www livoxtech com hub Searching for Keywords Search for keywords such as FOV and mount to find a topic If you are using Adobe Acrobat Reader to read this document press Ctrl F on Windows or Command F on Mac to begin a search Navigating to a Topic View a complete list of topics in the table of contents Click on a topic to navigate to th...

Page 3: ...Cable 6 GPS Sync Port and GPS Sync Cable 6 Gigabit Ethernet Port 8 Mounting Livox Hub 8 Dimensions With Port Covers 8 Dimensions Without Port Covers 8 Getting Started 9 External Power Supply 9 Connection 9 Usage 11 Output Data 11 Working States Working Modes 11 Integration of Point Cloud Data 12 Livox Viewer 12 Software Development Kit SDK 14 After sales Information 14 Appendix 14 Status LED Descr...

Page 4: ...layed in Cartesian or Spherical coordinates and can be changed using Livox Viewer Time Synchronization Time synchronization is supported by IEEE 1588 2008 PTPv2 and GPS delivering sub microsecond level time synchronization of point cloud data Livox SDK The Livox LiDAR Software Development Kit SDK is provided to help develop customizable applications using the point cloud data The precision of IEEE...

Page 5: ... 76825 0004 type port that connects to an external power source Only compatible with MOLEX 171692 0104 type connectors To view the ports on Livox Hub unscrew and remove the port covers Connectors Livox LiDAR Port There are nine Livox LiDAR ports available on Livox Hub and those nine Livox LiDAR ports have the same functionality Below is more information on the Livox LiDAR ports Figure 2 1 1 Livox ...

Page 6: ...ower cable description Power Port and Power Cable The Livox Hub power port and the ends of the power cable included with Livox Hub have the same functionality GPS Sync Port and GPS Sync Cable The Livox Hub GPS sync port and the ends of the GPS sync cable included with Livox Hub have the same functionality 1 2 3 4 Figure 2 2 1 Livox Hub power port Power Cable Connect A to the power port of Livox Hu...

Page 7: ... port GPS Sync Cable Connect A to the GPS sync port of Livox Hub and connect B to the GPS sync signal Refer to the Data Synchronization section for more information 1 2 3 4 5 500 25 A B 3 1 2 4 5 Figure 2 3 2 GPS sync cable Table 2 3 1 Livox Hub GPS sync port and sync cable description GPS Sync Signal Description Figure 2 2 2 GPS sync signal description t0 1000 ms t1 20 ms t1 200 ms t2 70 ms 9600 ...

Page 8: ... on the status LEDs Mounting Livox Hub Livox Hub is outfitted with four M3 mounting holes with a depth of 6 mm on the bottom and it can be mounted using M3 screws Livox Hub is already mounted with the port covers The port covers can be removed if there are spacial constraints when mounting or positioning Livox Hub However it is recommended to keep the port covers mounted to Livox Hub Only remove t...

Page 9: ... static IP mode by using Livox Viewer or the Livox SDK If Livox LiDAR sensors are connected to Livox Hub after the IP address is set make sure to disconnect the power source and connect again with the LiDAR sensors connected Otherwise the external power source cannot provide power to the LiDAR sensors connected DO NOT connect or disconnect the Livox LiDAR sensors to or from Livox Hub while powerin...

Page 10: ...ress 1 Connect Livox LiDAR sensors router external power source and computer by following Figure 4 2 1 2 Run Livox Viewer and Click to open Device Manager Select Livox Hub and click to open Properties Set the IP address of Livox Hub to static IP address Note that the static IP address of Livox Hub should be 192 168 1 X X can be set to any number between 2 to 233 3 Disconnect Livox Hub Livox LiDAR ...

Page 11: ...R sensors support the following message events Sync Fllow_up Delay_req Delay_resp GPS GPS is a way to precisely synchronize the point cloud sampling time using the sync pulse generated The time synchronization can be completed with a PPS signal and a NMEA GPRMC record PPS is the precise pulse per second and its rising edge is 1s GPRMC offers the UTC time of PPS The time sequence of PPS and GPRMC i...

Page 12: ...g Apply then click Stop Cali Livox Hub will automatically integrate the point cloud data and produce a single output The integration of point cloud data can be achieved by using the Livox SDK as well Refer to the SDK Communication Protocol for more information Livox Viewer Livox Viewer is a Windows software designed for Livox LiDAR sensors and Livox Hub Users can check real time point cloud data o...

Page 13: ...rties Click Livox Hub to view the current status of Livox Hub including the firmware version IP address and the type of coordinates Under the Hub Slot Power Options unselect a number to cut off the power supply of the corresponding LiDAR sensor 5 Click the triangle icon to the left of Livox Hub to view all the LiDAR sensors connected Click each LiDAR sensor to check the properties For each LiDAR s...

Page 14: ...int cloud data acquired from Livox LiDAR sensors to different scenarios SDK Communication Protocol There are two types of communication protocols between the user and a Livox LiDAR sensor and the protocol formats of these two kinds of data are different The specific functions and differences of these types of communications are as follows Control Command Data Configuration and query of LiDAR param...

Page 15: ...pecifications LiDAR Ports 9 Voltage Range 10 23 V DC Power Input Varies in different situations Operating Temperature Range 40 to 185 F 40 to 85 C Data Interface 1Gbps Ethernet Time Sync Protocol IEEE 1588 V2 PTP GPS Precision Time Weight Approx 865 g without port covers Approx 1352 g with port covers Dimensions 153 2 201 29 mm without port covers 208 201 29 mm with port covers Model LIVOX HUB The...

Page 16: ...ight 2019 Livox Tech All Rights Reserved Livox and Livox Mid are trademarks of Livox Technology Company Limited Windows is a registered trademark of Microsoft Corporation in United States and other countries ...

Reviews: