![LIVOLTEK GT3-17K-D User Manual Download Page 32](http://html1.mh-extra.com/html/livoltek/gt3-17k-d/gt3-17k-d_user-manual_1931325032.webp)
29
WIFI Module
Following
figure
show
inverter’s
interface
to
connect
WIFI accessory
,
please
refer user
manual
of
accessory
for
connecting
method
and
its
setting
.
Table 5 4 WIFI & GPRS &
Modules Description
.
RS485
WIFI module implements communication with Cloud server through
wireless network to monitor PV inverter's data status.
For more details, refer to WIFI Product Application Manual.
You can buy WIFI communication
modules from our company.
WIFI
NOTE
Module
Function description
5
.
5 Installation Verification
Check the following items after the inverter is installed according to Table 5
.
5
.
1
.
No other objects put on the PV inverter
.
2
.
All screws
,
especially the screws used for electrical connections
,
are tightened
3
.
The PV inverter is installed correctly and securely
.
4
.
Ground
,
AC
,
DC
,
and
Communications
cables
are
connected
tightly
/
correctly
and
securely
.
5
.
Check there is no open circuit or short
-
circuits at AC and DC terminals using multimeter
.
6
.
Waterproof connectors at AC terminals and RS485 ports are plugged with waterproof
plugs tightly.
7
.
Covers at AC terminals are tightened
.
8
.
Idle terminals are sealed
.
9
.
All safety warning symbols are intact and complete on the inverter
.
Table 5
.
4 Self-check items after installation