17
4 4 2 Installation Mode Requirements
. .
Install the inverter upright or at a maximum back tilt of 15 degrees to facilitate heat dissipation
.
,
.
. .
Below are some correct / wrong installation modes as shown in Figure 4 8&4 9
Figure 4 8 The correct installation mode
.
The correct installation mode
upright
back tilt
Figure 4 9 The wrong installation modes
.
The wrong installation will lead to failure of the inverter operation
.
NOTICE
The wrong installation mode
Horizontally
Upside down
-
Step 1
Support-mounting the inverter is recommended. Tighten the support and rear panel using
M12 bolt and the required torque is 42N.m as shown in Figure 4 10.
,
.
4 5 Support-mounting the Inverter
.
Figure 4 10 Securing a rear panel
.