3
Important Safety Instructions
3-5
Parts List
6
Assembly
6-10
Operation
11
Cleaning and Maintenance
11
Technical Specifications
12
Warranty
12
Warning!
Please read and understand this entire manual before attempting to assemble,
operate or install the product. Failure to follow the dangers, warnings and cautions contained
in this instruction manual may result in a fire or explosion causing damage to property, serious
bodily injury or death.
•
The installation of this product must conform with local codes or, in the absence of local codes, with either the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, OR CAN/CGA-B149.1, National Gas and Propane Installation
Code.
•
FOR OUTDOOR USE ONLY! This appliance shall be used only outdoors in a well-ventilated space and shall not be
used in a building, garage, or any other enclosed area.
•
USE PROPANE GAS ONLY!
•
Use only with a propane gas tank (sold separately). Do not attach to a remote gas supply.
•
Propane gas is not natural gas. Only use propane gas for this fireplace.
•
The conversion or attempted use of natural gas in a propane unit or propane gas in a natural gas unit is
dangerous and not recommended. Doing so may void your warranty.
•
Never use charcoal or any other solid fuel in the fireplace.
•
During ignition procedure, you should never get your face close to the burner as an unnoticed flame may light up
and cause injury.
•
LP GAS WARNING: Do not exceed 1/4 in. depth of pumice stones directly above burner holes. Applying too much
media may result in unburned gas pooling in fireplace. Ventilation is required to allow fresh air into enclosure
and for any residual gas to escape.
•
If you see, smell or hear the hiss of escaping gas from the propane gas tank: 1. Disconnect propane gas tank. 2.
Do not attempt to correct the problem yourself. 3. Get to your gas supplier and/or the fire department for help.
•
Do not operate the fireplace if there is a gas leak present.
•
Never use a flame to check for gas leaks.
•
The max. inlet supply pressure: max. gas supply 11" w.c. (2.74 kPa).
•
The gas pressure regulator provided with the fireplace must be used.
•
Use LP propane gas tanks only with these required measurements: 12" (30.5 cm) (diameter) x 18" (45.7 cm)
•
(tall) with 20 lb (9 kg) capacity maximum.
•
Propane tank used must include a collar to protect the propane gas tank valve.
•
Never fill the propane gas tank beyond 80% full.
•
Propane gas tank supply system must be arranged for vapour withdrawal.