background image

Components:

Hand wand 

– placed in the side pocket (outside LAF arm/RAF arm), controls all motors and functions (reclining, 

power headrest, lifting, etc.) via a direct connection with motors. . 

AC wall plug 

– connects the power transformer to the power outlet.

DC cord 

– connects the power transformer to the DC socket (mounted on the rear bottom of LAF arm/RAF arm 

stump).

DC socket 

– receives power from DC cord then transfer to motors.

Power Transformer 

– A box-shaped unit to transfer 110V AC power to 25V DC power to supply for the furniture.

Junction Box 

– splitter/extension cord connecting the power transformer to multiple motors/air baddders/heat padding/

hand wand.

Seat / Headrest Motor 

– motors mounted on mechanism to drive movement on seat/headrest via hand wand control.

Air Bladders- 

mounted inside lower section of back, inflate the air bladders via hand wand control. Turns off 

automatically after 30 minutes of use as safety feature.

Heating pad 

– mounted inside lower section of back, produces heat via hand wand control. Turns off 

automatically after 30 minutes of use as safety feature.

Summary of Contents for 267669

Page 1: ...2028 MAJORCA POWER RECLINER W AIR MASSAGE USER MANUAL...

Page 2: ...Abox shaped unit to transfer 110VAC power to 25V DC power to supply for the furniture JunctionBox splitter extensioncord connecting the power transformer to multiple motors air baddders heat padding...

Page 3: ...lugged in 2 Broken side switch 3 Broken DC socket 4 Broken power transformer especially when ALL motors stops working on one unit 5 Power cords damaged 6 Motors failure NOTE In some cases a button on...

Page 4: ...Instruction for hand wand...

Page 5: ...lluminated but no heat is produced If the HEAT button is illuminated but the heat pad is not producing heat the heat pad could have become disconnected 1 Unplug the piece of furniture from the wall ou...

Page 6: ...the seat back and footrest if applicable Lumbar will open and close the lumbar air cushion All open buttons are located on the right side of the Hand Control and all close buttons are located on the l...

Page 7: ...zipper pouch 6 Unzip the pouch and locate the Hand Control cord 7 Ensure that there are no frayed pinched exposed or otherwise damaged wires Do not connect the Hand Control if the cord is damaged in a...

Page 8: ...ion contact your furniture provider so they may replace or repair the faulty part ReclineM otor Cord Error Lumbar Air cushion does not inflate If the Lumbar air cushion does not inflate the air hose m...

Page 9: ...a numerical button or the MODE button will reset the 30 minute timer Note Using the Lumbar function will stop all other massage features If the massage feature is running and either Lumbar button is p...

Page 10: ...Air Hose Connector 10...

Page 11: ...POWER RECLINER PARTS...

Page 12: ...cable Check connection security and integrity of motor s 2 pin cable 1 Check power cords integrity and connection to transformer 2 If power cords undamaged and connection secured replace power transfo...