SECTION 5: INSTALLATION
10
SECTION 5: INSTALLATION
General Notes & Requirements
•
A qualified technician must complete the installation of this built-in appliance. Proper
installation is the customer’s responsibility.
•
Cabinet cutout dimensions must be used as indicated. All contact surfaces between the
warming drawer and the cabinet must be solid and level.
•
Carefully check the location where the drawer is to be installed. The drawer should be
placed for convenient access. Ensure you will have enough room to open the drawer fully,
and that it will not be blocked by any other permanently installed furniture or appliance.
•
The installation dimensions create a fully flush installation with the drawer face.
•
Ensure you have everthing necessary to ensure proper installation before proceeding.
Electrical & Environmental Specifications
•
Important: See “Grounding Instructions” on Page 2.
•
CAUTION: The warming drawer incorporates a non self-resetting thermal cut out. This
means if the unit overheats and triggers the thermal cut out, the warming drawer will be
reset by unplugging the unit from the supply mains. Therefore the plug must be acces-
sible to allow the customer to easily unplug the appliance when needed.
•
The correct voltage, frequency, and amperage must be supplied to the electrical outlet
from a grounded, single phase circuit that is protected by a properly sized circuit breaker
or time-delay fuse.
•
It is the owner’s responsibility to ensure that the electrical outlet is installed by a qualified
electrician. The electrical installation must comply with the latest revision of the National
Electric Code ANSI/NFPA 70 and local codes and ordinances.
•
If the electrical service provided does not meet the product specification, or does not con-
form to the NEC or local standards, do not proceed with the installation. Call a licensed
electrician to correct the electrical service before proceeding.
•
Keep the electrical cord away from hot surfaces.
•
The power supply requirements shown below are for reference only. If they do not agree
with those listed on the product data label, use the requirements on the product data
label.
Nominal Electrical Supply Requirements - 120V
120 VAC, 60 Hz, 15 Amp., dedicated circuit
The warming drawer is supplied with a 60” (152.4 cm) power cord
with a thre prong grounded plug.
Total Connected Load 2 Amp
Nominal Electrical Supply Requirements - 220V
220 VAC, 50 Hz, 15 Amp., dedicated circuit
The warming drawer is supplied with a 60” (152.4 cm) power cord
with a grounded plug (type varies by country).
Total Connected Load 0.6 Amp
Overall Dimensions - Top View with Open Drawer
Chassis
Open Drawer
19.895” (50.53 cm)
18.295” (46.47 cm)
16.156”
(41.04 cm)
.675”
(1.7 cm)
14.16”
(35.97 cm)
7/8”
(2.2 cm)
Overall Dimensions - Drawer Front
19.9”
(50.55 cm)
6.58”
(16.7 cm)
8.5”
(21.59 cm)
These installation instructions are for customers that are planning to install the warming drawer
into custom mill work or cabinetry.
Installer: In the interest of safety and to minimize problems, read these installation instructions
completely and carefully before you begin the installation process. Leave these installation
instructions with the customer.
Customer: Keep these installation instructions for future reference and the local electrical
inspector’s use.