background image

 

 

16

CHAPTER 4: TROUBLESHOOTING

 

4.1 Troubleshooting – No Power to the Console 

 

Symptom

The power switch is in the on position, but the console will not turn on.   

 

Reason

: 

1.  The outlet is not providing the correct power, or the power cord / switch is defective. 

2.  The power receptacle or power wiring to the MCB is defective. 

3.  The MCB is defective. 

4.  The console cable or console is defective. 

 

   

Solution

   

 

 

1. First check to see if the power switch is lit. If it is not, try a different outlet. If the power switch still does not 

 

 

light up with a known good outlet, replace the power switch.     

 

 

2. Check to see if the MCB has power. There is a red power LED on the MCB that should be lit. 

 

 

 

 

 

 

 

 

 

 

3. If the MCB does not have power, check the connection of the power wiring from the power receptacle to the 

 

 

MCB. Use a multi-meter to measure AC1 and AC2, AC voltage shall be same as local’s standard voltage   

  (110V-240V) 

               

 

a. If AC voltage value is standard, replace the MCB as it is defective.     

 

 

 

 

 

 

 

 

 

 

4. Make sure that the input to the console's power supply is a 12VDC, use a multi-meter to measure the voltage 

 

 

of the four pins in the figure below, pins 1 and 2 should be 12VDC and pins 7 and 8 should be ground.   

 

Summary of Contents for LS15.0E

Page 1: ...1 LS15 0T and LS15 0E Service Manual ...

Page 2: ...Test Tab 10 2 7 Engineering Mode Error Log Tab 11 2 8 Engineering Mode Service Log Tab 12 CHAPTER 3 ELECTRICAL DIAGRAM 3 1 Electrical Diagram LS15 0T 14 3 2 Electrical Diagram LS15 0E 15 CHAPTER 4 TROUBLESHOOTING 4 1 Troubleshooting No Power to the Console 16 4 2 Troubleshooting System Will Not Boot 18 4 3 Troubleshooting No Console Response 19 4 4 Troubleshooting Touch Panel Issues 20 4 5 Trouble...

Page 3: ...3 CHAPTER 1 SERIAL NUMBER LOCATION 1 1 Serial Number Location LS15 0T ...

Page 4: ...4 CHAPTER 1 SERIAL NUMBER LOCATION 1 2 Serial Number Location LS15 0E ...

Page 5: ...PEED DOWN keys at the same time for 3 5 seconds LS15 0E press and hold the RESISTANCE UP and DOWN keys at the same time for 3 5 seconds 1 The Engineering Mode parameter list will be displayed on the screen 2 Select the parameter by touching the parameter list 3 Set all information by using the touch panel 4 Press the Home key to save the change to the parameter and exit Engineering Mode 1 2 3 4 ...

Page 6: ...ot editable Cannot be modified Accumulated Time Total time not editable Cannot be modified GUI Board Information UI Software Version Application version not editable Cannot be modified IO version Sub UCB software version not editable Cannot be modified OS Version Operation system version not editable Cannot be modified MCB Information MCB Type The frame MCB type for example 2 75HP digital MCB Cann...

Page 7: ...or This is the minimum incline motor setting Do not edit as it can cause the incline motor to bind 26 Max Incline ADC The maximum ADC data for the incline motor This is the maximum incline motor setting Do not edit as it can cause the incline motor to bind 1150 Current Incline ADC Current ADC data for the incline motor This is the current incline motor setting Cannot be modified FIRST BOOT Selects...

Page 8: ...ime Default 15 Min This option enables you to set user default workout time Max 120 Minutes Min 5 Minutes Pause Time Default 5 Minutes This option enables you to set workout pause time the console will be reset beyond this time Max 5 Minutes Min 1 Minutes Warm Up Time Default 1 Minute This option enables you to set user s warm up time Max 5 Minutes Min 1 Minutes Cool Down Time Default 1 Minute Thi...

Page 9: ...art rate programs Max 90 Min 50 Brightness Brightness Default 75 This option enables you to set the LCD panel brightness Max 100 Min 20 2 5 Engineering Mode Region Tab The Region Tab sets the Date Time and Clock Version that will be displayed to a user Engineer Mode Region Function and Default Descriptions Modified Date This is the current date setting Time This is the current time setting Units S...

Page 10: ...splay Test To test the reliability of the TFT LCD and Touch panel Key Test To test the function of the keypads Audio Test To test the audio output Hardware Test To test the heart rate drive and incline motors Display Test Cycles between red green and blue as you touch the screen Display Test Key Test Audio Test Hardware Test ...

Page 11: ...Display Test Use your finger to draw a line following the instructions on the screen If the test fails press CONTINUE This brings you directly into the calibration screen Key Test Press any key and the display will show the definition the function and the code of the key ...

Page 12: ...tab allows a service technician to test the RPM sensor the incline motor and or the heart rate Changing a setting should cause the belt incline motor or heart rate to operate 2 7 Engineering Mode Error Log Tab Error Log The console will automatically display a history of errors on the unit ...

Page 13: ...13 CHAPTER 2 ENGINEERING MODE 2 8 Engineering Mode Service Log Tab Service Log Allows the club service provider to keep track of the service history ...

Page 14: ...14 CHAPTER 3 ELECTRICAL DIAGRAMS 3 1 Electrical Diagram LS15 0T ...

Page 15: ...15 CHAPTER 3 ELECTRICAL DIAGRAMS 3 2 Electrical Diagram LS15 0E ...

Page 16: ...the power switch still does not light up with a known good outlet replace the power switch 2 Check to see if the MCB has power There is a red power LED on the MCB that should be lit 3 If the MCB does not have power check the connection of the power wiring from the power receptacle to the MCB Use a multi meter to measure AC1 and AC2 AC voltage shall be same as local s standard voltage 110V 240V a I...

Page 17: ... examples of bad connections below If it is check the output of the MCB If it is not 12VDC replace the MCB OK UCB connection floating high cable connection not inserted fully b If the 12VDC power supply is ok check the connection of the LVDS interface wire to the display Check the LVDS wire for any breaks or loose connections if none found replace the display 12VDC GND LVDS 接口 ...

Page 18: ...TING 4 2 Troubleshooting System Will Not Boot Symptom The LCD has a back light but the system does not boot up does not display the LS logo Reason 1 The system software has crashed Solution 1 The system crashed replace the UCB ...

Page 19: ... is over rated current for more than 4 seconds Motor power issue replace the motor 4 Rampage The motor power components are damaged or speed up too fast Motor power issue replace the motor 5 Safety Key Not Connected The safety key fell is not connected Re attach or replace the safety key 6 Incline is Stuck There is no signal received during the working of incline motor Lift relay defective or the ...

Page 20: ...r has a deviation press the ENTER and STOP keys together for 3 5 seconds to enter the screen calibration mode Follow the prompts to calibrate the touch screen 2 Check the touch screen for visible damage indentation or deformation If any damage is found replace the entire display 3 Check the connection of the FPC wire at the GUI board Even if well connected disconnect and reconnect and re calibrate...

Page 21: ...her and check to make sure it is well connected with no breaks 2 Check continuity of the HR grip wiring a Place one terminal of a multi meter set for resistance on the HR grip wiring at the HR grip and the other terminal on the HR grip wiring at the console An ohm reading of around 1 should be expected if the reading is higher than 1 replace the HR grip wiring 3 Confirm whether the heart rate boar...

Page 22: ...e is obsolete 4 The head phone wire or board is defective Solution 1 Confirm whether the speaker wire is well connected with the GUI board 2 If well connected make sure that the audio output short circuit terminal is present and tight 3 Update the console software see Section 5 1 4 If the speakers have sound output but headphones have no sound output replace the headphone wire If problems persist ...

Page 23: ...ame is the same 1 Choose the correct OS nk rom file according to the LCD size and place the file under this root in the USB 2 Update the software accordingly LS15 0E and LS15 0T use the sample software file LivestrongDeploy CAB Place the corresponding file under this root in the USB 3 Place the update config file under this root in the USB 4 Light up the console and insert the USB The file will up...

Page 24: ...nguish 3 Also place the Update config file under this root in the USB 4 Light up the console and insert the USB The IO will update automatically Note The file update config should be under this root in the USB when updating The software file and the IO file need to distinguish between LS15 0E and LS15 0T and cannot be placed into the USB together at the same time Placing the NK rom software file a...