 Proper  procedure   

and handling!

  

Install the light so that it is pro-
tected from moisture, dirt and 
excessive heating. Avoid fitting 
the lights in bathrooms or simi-
lar rooms.

 

 Use only 230 V ∼ bulbs with a 
GU10 socket and a maximum 
power of 40 watt.

  

The distance between two  
recessed light spots must be at 
least 20 cm. The fitting area 
over the lamp fitting must be 
at least 10 cm and to the side 
at least 10 cm (see Fig. H).

 

Prior to installation

Important:

 The electrical connection must be 

established by a qualified electrician or a person 
trained to perform electrical installations. This 
person must be familiar with the properties of 
the light and the connection regulations. The  
cables leading to the lights must be according 
to the local regulations.

Before installation, ensure that the circuit to which 
the light will be connected, is not live. To do so, 
remove the fuse or switch off the circuit breaker 
at the fuse box. To check the power is off, use a 
circuit tester.

 

Start-up

  

Using a hollow drill (ø 68 mm), drill the 6 holes 
at the installation point. Take care to observe 

the minimum distance between two recessed 
light spots. This must be at least 20 cm.

  

Insert the retaining springs 

4

 into the spot-

lights (see Fig. B and C). The small lug of 
the retaining springs must lie on the inside 
of the housing of the lamp 

1

 so that the  

retaining springs are tensioned.

  

Open the mains socket 

9

 by unscrewing 

the cover 

5

 with a screwdriver (see Fig. D).

  

Undo the cable holder 

6

 using a screw-

driver.

 

 Install the power lines into the tubes 

10

 and 

then

 

connect the power line to the terminal 

block 

7

 (see Fig. D) and tighten the cable 

holder using a screwdriver. 

Hint: 

Make sure the power lines are com-

pletely covered by the tubes inside the 
mains socket.

  

Close the mains socket, by tightening the 
cover using a screwdriver.

  

Place the fitting 

8

 of the mains socket onto 

the bulb 

2

 including the lamp housing and 

turn the bulb until tight with a ¼ turn in a 
clockwise direction (see Fig. E).

  

Before fitting the recessed light spot, remove 
possibly present insulating material from the 
vicinity of the mains socket and the spots.

  

Fold the two retaining springs upwards and 
guide the recessed light spots with the con-
nection cable into the installation opening 
(see Fig. F).

  

After you have pushed the spot into the open-
ing, the retaining springs unfold and fix the 
recessed spot in place (see Fig. G).

  

Proceed in the same way with the other five 
recessed light spots.

  

The recessed light spots are now ready for 
use.

  

Now switch the power back on.

  

replacing a bulb

caUTIon! rISk of elecTrIc 
SHock!

 To replace the bulb, first 

disconnect the light from the mains 

Summary of Contents for 91133

Page 1: ...IAN 91133 HALOGEN RECESSED SPOTLIGHTS HALOGEN EINBAULEUCHTEN SET Bedienungs und Sicherheitshinweise HALOGEN RECESSED SPOTLIGHTS Operation and Safety Notes...

Page 2: ...GB IE Operation and Safety Notes Page 4 DE AT CH Bedienungs und Sicherheitshinweise Seite 8...

Page 3: ...3 A C E G B F H 1 2 3 4 1 4 1 D 5 10 7 6 9 4 2 4 8 9 4 4 4 4 approx 10cm approx 10cm approx 10 cm...

Page 4: ...installed bulbs 6 Mains connectors 12 Retaining springs 12 Tubes 1 Operating instructions General safety instructions PLEASE READ THE INSTRUC TIONS FOR USE PRIOR TO USE PLEASE KEEP THE INSTRUC TIONS...

Page 5: ...uctive surfaces Prevent fire and injury hazards RISK OF INJURY Check each bulb and lamp glass for damage immediately after un packing Do not fit the light if the bulbs and or lampshades are faulty RIS...

Page 6: ...e Fig B and C The small lug of the retaining springs must lie on the inside of the housing of the lamp 1 so that the retaining springs are tensioned Open the mains socket 9 by unscrewing the cover 5 w...

Page 7: ...n a clockwise direction Secure the bulb to the lamp housing using the spring ring Check for correct fitting see Fig A Cleaning and care CAUTION RISK OF ELECTRIC SHOCK Disconnect the light from the mai...

Page 8: ...mit vormontierten Leuchtmitteln 6 Netzanschlussdosen 12 Haltefedern 12 Schutzschl uche 1 Bedienungsanleitung Allgemeine Sicherheitshinweise VOR GEBRAUCH BITTE DIE BEDIENUNGSANLEITUNG LESEN BEDIENUNGSA...

Page 9: ...g der Leuchte bereinstimmt 230V Vermeiden Sie unbedingt die Ber hrung der Leuchte mit Wasser oder anderen Fl ssig keiten Installieren Sie die Leuchte nicht auf feuchten oder leitenden Unterlagen Verme...

Page 10: ...Person erfolgen Diese muss Kenntnis ber die Eigenschaften der Leuchte und Anschlussbestimmungen haben Die Zuleitung zu den Leuchten muss den rtlichen Bestimmungen entsprechen Stellen Sie vor der Insta...

Page 11: ...Lassen Sie die Leuchte vollst ndig abk hlen L sen Sie den Federring 3 aus dem Leuchten geh use 1 Ziehen Sie das defekte Leuchtmittel 2 mit der Fassung 8 etwas aus dem Leuchtenge h use Benutzen Sie zu...

Page 12: ...rfahren Sie bei Ihrer Gemeinde oder Stadtverwaltung Entsorgen Sie das Ger t den Artikel und Leuchtmittel keinesfalls in den normalen Hausm ll Das Ger t Den Artikel und Leuchtmittel ber einen zugelasse...

Page 13: ...IAN 91133 OWIM GmbH Co KG Stiftsbergstra e 1 D 74167 Neckarsulm Model No Z31669A Z31669B Version 07 2013 Last Information Update Stand der Informationen 07 2013 Ident No Z31669A B072013 GB...

Reviews: