9
GB/IE
Installation
When selecting the mounting location, pay
attention to the following:
1. The solar cell
6
requires direct sunlight when
possible. Ideally, the solar cell surface will be
directed to the south. The horizontal direction
of the solar cell is dependent on mounting
on a vertical wall.
2. Depending on the mounting height (ideally
at 2 m) the sensor
7
has a detection range
of max. 5m with a detection angle of 100°
horizontally and 90° vertically.
3. Be sure the sensor is not illuminated by street
lighting at night. This can influence the effect.
For model HG00375A:
Fix the mounting
plate
2
using the provided rawlplugs
1
(ø 6 mm) and the provided screws
3
(Fig. A).
For model HG00375B / HG00375C:
Fix the mounting plate
2
using the provided
rawlplugs
1
(ø 6 mm) and the provided
screws
3
. Ensure that the arrow on the
marking of the mounting plate ( UP) is show-
ing vertically upward (Fig. A).
Note:
The enclosed mounting material is
suitable for ordinary masonry construction.
Other wall substrates may require other fas-
tening materials. Seek specialist advice when
in doubt.
Set the ON / OFF switch
11
to the position
„ON“ to start the operation of the light (For
HG00375A, the ON/OFF switch is inside
the lamp shade
13
at the base. Open the
lamp shade to set the switch.) (Fig. G).
Note:
In the „OFF“ position both the light
and the charging function are disabled.
For model HG00375A:
Fix the light
onto the mounting plate using the provided
screws
12
(Fig. B).
For model HG00375B / HG00375C:
Attach the device to the mounting plate in
such a way that the hangers
4
of the
mounting plate grip in the receivers
5
on
the back of the device. Slide the device
downwards until the hangers click into
place in the receivers (Fig. B).