7
ILLUSTRATED INSTRUCTIONS
FOR MAINTENANCE
Warning
Before any maintenance or adjustment to
BedShaper
®
is performed, always remember to:
stop engine. Disconnect spark plug wire and
allow components to cool before servicing.
Clean Blade Shield:
1. Make sure blade is cool.
2. Remove two cover bolts from blade shield.
Open hinged shield.
3. Remove debris from shield and behind blade
with a dowel or similar object. Never use hand-
blade may be sharp.
4. Close shield back into position. Securely fasten
shield with two bolts. Never operate without
shield securely fastened.
BedShaper
®
Maintenance Chart- Service Intervals
Item
Daily
25 Hrs.
Yearly
Page
Visual Inspection
■
Engine
Refer to Engine Manual
Clean Blade Shield
■
6
Check Wear on Blade
■
7
Lubricate Blade Arm Zerk Grease Fittings
■
7
Check Drive Belts
■
8
Lubricate Blade Shaft & Axle Bearings
■
8
Chain Tension
■
8
End of Season Cleaning
■
8
Table 5-1